Air
General Data/Electrical Data
RA13 Series
8
Physical Data
PHYSICAL DATA
Model No.
RA1318A
RA1324A
RA1330A
RA1336A
RA1342A
RA1348A
RA1360A
Nominal Tonnage
1.5
2.0
2.5
3.0
3.5
4.0
5.0
Valve Connections
Liquid Line O.D. – in.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Suction Line O.D. – in.
3/4
3/4
3/4
3/4
7/8
7/8
7/8
Refrigerant (R410A) furnished oz.¹
56
66
78
92
111
112
154
Compressor Type
Scroll
Outdoor Coil
Net face area – Outer Coil
5.9
9.1
9.1
12.1
14.2
14.8
18.8
Net face area – Inner Coil
—
—
—
—
—
—
—
Tube diameter – in.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Number of rows
1
1
1
1
1
1
1
Fins per inch
22
18
22
22
22
22
22
Outdoor Fan
Diameter – in.
20
20
20
20
20
24
26
Number of blades
2
2
3
3
2
3
2
Motor hp
1/8
1/8
1/4
1/4
1/8
1/6
1/5
CFM
2040
2325
2795
2900
2465
4145
3870
RPM
1075
1075
1075
1075
1075
850
820
watts
144
137
189
186
176
280
233
Shipping weight – lbs.
127
129
140
150
173
182
192
Operating weight – lbs.
120
122
133
143
166
175
185
Electrical Data
Line Voltage Data (Volts-Phase-Hz)
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
Maximum overcurrent protection (amps)²
20
25
30
35
40
50
60
Minimum circuit ampacity³
13
15
18
21
24
29
35
Compressor
Rated load amps
9.7
11.2
12.8
15.4
17.9
21.8
26.4
Locked rotor amps
46
60.8
64
83.9
112
117
134
Condenser Fan Motor
Full load amps
0.7
0.7
1.3
1.3
0.7
1
1.2
Locked rotor amps
1.3
1.3
2.5
2.5
1.3
2
2
Line Voltage Data (Volts-Phase-Hz)
—
—
—
208/230-3-60
208/230-3-60
208/230-3-60
208/230-3-60
Maximum overcurrent protection (amps)²
—
—
—
20
30
30
35
Minimum circuit ampacity³
—
—
—
15
18
19
22
Compressor
Rated load amps
—
—
—
10.4
13.2
13.7
16
Locked rotor amps
—
—
—
73
88
83.1
110
Condenser Fan Motor
Full load amps
—
—
—
1.3
0.7
1
1.3
Locked rotor amps
—
—
—
2.5
1.3
2
2
Line Voltage Data (Volts-Phase-Hz)
—
—
—
480-3-60
480-3-60
480-3-60
480-3-60
Maximum overcurrent protection (amps)²
—
—
—
TBD
TBD
TBD
TBD
Minimum circuit ampacity³
—
—
—
TBD
TBD
TBD
TBD
Compressor
Rated load amps
—
—
—
TBD
TBD
TBD
TBD
Locked rotor amps
—
—
—
TBD
TBD
TBD
TBD
Condenser Fan Motor
Full load amps
—
—
—
TBD
TBD
TBD
TBD
Locked rotor amps
—
—
—
TBD
TBD
TBD
TBD
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.