Rheem P-M207 Скачать руководство пользователя страница 52

52

CALL

OUT

DESCRIPTION

206A

266A

336A

406A

HM

HEAT EXCHANGER - METAL

1-HM

Heat Exchange Assy.Copper ASME CI 

010051F

006727F

010053F

010054F

Heat Exchange Assy.Cupro Nickel ASME CI 

010360F

010361F

010362F

010363F

   2-HM

Inlet/Outlet Header ASME CI Complete

006730F

006730F

006730F

006730F

Inlet/Outlet Header ASME CI

012319F

012319F

012319F

012319F

       15-HM

Inlet & Outlet Flange

003766F

003766F

003766F

003766F

         16-HM

Flange Gasket 1 1/2" Connections

062236B

062236B

062236B

062236B

Flange Gasket 2" Connections

800080B

800080B

800080B

800080B

   3-HM

Return Header ASME CI

006731F

006731F

006731F

006731F

   4-HM

Tube Bundle Copper ASME *

010055F

006733F

010057F

010058F

Tube Bundle Cupro Nickel ASME *

010368F

010369F

010370F

010371F

        5-HM

Baffle

010038F

005261F

010040F

010041F

        6-HM

Stud Bolt Kit

007870F

007870F

007870F

007870F

        7-HM

Header Gasket (9)

800014B

800014B

800014B

800014B

   8-HM

Unitherm Governor

062234B

062234B

062234B

062234B

        9-HM

U.G. Retainer Spring

013792F

013792F

013792F

013792F

  18-HM

U.G. Plug

013738F

013738F

013738F

013738F

  10-HM

Bypass Valve

062235B

062235B

062235B

062235B

       11-HM

Bypass Spring

850252

013794F

013794F

013794F

   12-HM

Drain Valve

013793F

013793F

013793F

013793F

   13-HM

Sensor Well

003765F

003765F

003765F

003765F

   14-HM

Well Retaining Clip

300203

300203

300203

300203

17-HM

Rear Drain Plug & Cover

005264F

005264F

005264F

005264F

J

CONTROL BOX

1-J

Transformer 120/240/24V

006736F

006736F

006736F

006736F

2-J

Rocker Switch 

009493F

009493F

009493F

009493F

M

MISCELLANEOUS COMPONENTS

1-M

Pressure Switch 1.75 PSI

006737F

006737F

006737F

006737F

Pressure Switch 11 PSI

    Special-See Water Pressure Switch Adj.

009133F

009133F

009133F

009133F

2-M

Thermostat Knob 

009499F

009499F

009499F

009499F

     3-M

Thermostat Shaft MV

800307

800307

800307

800307

4-M

Knobstop 

006886F

006886F

006886F

006886F

5-M

Thermal Fuse 

005899F

005899F

005899F

005899F

6-M

PRV 125 PSI (Optional)

008091F

007224F

007224F

007224F

7-M

Deliming Kit

052871F

052871F

052871F

052871F

8-M

Wire/Harness Millivolt

010386F

010386F

010386F

010386F

Wire/Harness IID

009490F

009490F

009490F

009490F

9-M

Control Bezel MV (Includes Dial Decal)

009489F

009489F

009489F

009489F

     10-M

Dial Decal MV

009858F

009858F

009858F

009858F

11-M

Control Bezel  (Includes Switch Decal)

    Units manufactured prior to 5/2011 

009491F

009491F

009491F

009491F

    Units manufactured From 5/2011

013491F

013491F

013491F

013491F

     12-M

Switch/Decal-Membrane

    Units manufactured prior to 5/2011 

009492F

009492F

009492F

009492F

    Units manufactured From 5/2011

013492F

013492F

013492F

013492F

13-M

Control Bezel Cover

009487F

009487F

009487F

009487F

14-M

Gasket Insulation  (Swaybrace & Jacket Top)   

010350F

010350F

010350F

010350F

15-M

Touch-up Paint (Green)

750125

750125

750125

750125

Touch-up Paint (Dark Gray)

750126

750126

750126

750126

Touch-up Paint (Cool Dark Gray)

750256

750256

750256

750256

Touch-up Paint (Warm Dark Gray)

750258

750258

750258

750258

16-M

Tie Down Bracket (Optional)

011636

011636

011636

011636

17-M

Texas Code Add/On (ASME Only)

012011

012011

012011

012011

P

PILOT

1-P

Pilot Nat. MV

600525B

600525B

600525B

600525B

Pilot Pro. MV

600575B

600575B

600575B

600575B

2-P

Pilot Nat & Pro IID   

002003F

002003F

002003F

002003F

    3-P

Pilot Orifice Nat. MV

003901F

003901F

003901F

003901F

Pilot Orifice Pro. MV

003902F

003902F

003902F

003902F

    4-P

Pilot Orifice Nat. IID .020

003903F

003903F

003903F

003903F

Pilot Orifice Pro. IID .012

004308F

004308F

004308F

004308F

    5-P

Pilot Generator MV

600019B

600019B

600019B

600019B

6-P

Pilot MTG Bracket MV

010352F

010352F

010352F

010352F

7-P

Pilot Mounting Bracket IID 

306692

306692

306692

306692

8-P

Lighter Tube (MV Units Only)

062996

062996

062996

062996

9-P

Pilot Tube

004078F

004078F

004078F

004078F

10-P

Hi Tension Wire IID with Pilot Electrode

007864F

007864F

007864F

007864F

11-P

Pilot Shield 

010351F

010351F

010351F

010351F

R

REFRACTORY

1-R

Refractory Common Lt & Rt  

010088F

010088F

010088F

010088F

2-R

Refractory Uncommon (Front & Rear)

010089F

010090F

010091F

010092F

3-R

Refractory Retainer Kit   

010387F

010388F

010389F

010390F

*WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also

damaged the bypass valve and Unitherm Governor.  We recommend you replace the Unitherm Governor and

inspect the bypass assembly.  Failure to do so could cause premature failure of this replacement part.

ATMOSPHERIC HEATERS

Содержание P-M207

Страница 1: ...your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and servic...

Страница 2: ...age the heater providing the water is balanced Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water unless controlled they can lead to excessive chlorine...

Страница 3: ...r Reversal Procedure 26 Electrical Wiring 26 Millivolt Models 26 Advanced Flame Technology AFT Models 27 Transformer Wiring 28 Wiring Diagram Millivolt Mechanical Therm 29 Wiring Diagram AFT Models At...

Страница 4: ...s an easy task The upper front panel of the heater contains the control center that allows you to turn the heater On or Off and adjust the temperature set tings for the pool or spa The temperature ran...

Страница 5: ...P Read the safety information above 2 Set the thermostat on the lowest setting 3 Turn On Off switch to the Off position 4 Remove heater door panel 5 Push in gas control knob slightly and turn clockwis...

Страница 6: ...ormation above 2 Set the thermostat to the lowest setting 3 Turn off all electrical power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do...

Страница 7: ...manual gas control to the heater SECTION 2 CAUTION Elevated water temperature can be hazardous The U S Consumer Product Safety Commission has these guidelines 1 Spa water temperatures should never exc...

Страница 8: ...re not moving water or your gauge is broken Try to get the pump to run at its normal flow rate CAUTION Combustion air must not be contaminat ed by corrosive chemical fumes which can damage the heater...

Страница 9: ...higher temperatures are reached Operating the heater for prolonged periods with pool water below 50 F can seriously damage the heater and is not cov ered by the warranty For cold climate areas please...

Страница 10: ...the heater STANDARD UNIT POLYMER HEADERS ASME UNIT CAST IRON HEADERS 1 Pagoda top 1 Pagoda top 2 2 CPVC union with O rings 2 2 In Out flanges 2 3 Plastic pipe finish flange for gas line 3 1 1 2 flange...

Страница 11: ...ool Heaters All heaters can be used either indoor or outdoors The appropriate top designated for each type of use is required If necessary the top can be changed at a later date to change from outdoor...

Страница 12: ...NS Top 30 Drafthood Back 6 Front Alcove Open Right Side 12 Water Side Vent 6 Left Side 6 Floor 0 Opposite Water Side OUTDOOR INSTALLATION Top Unobstructed Outdoor Stack Top 36 Stackless Top Floor 0 Ri...

Страница 13: ...any building The top surface of the heater shall be at least 3 ft above any forced air inlet or intake ducts located within 10 ft horizontally For installations in Canada pool heaters shall not be in...

Страница 14: ...eld Supplied Ea Pallet Anchor Bracket Use hole closest to unit 4 total 1 1 4 x 1 3 4 S S Tapcon Bolt Washer Field Supplied Ea Pallet Anchor Bracket Use hole closest to unit 4 total 2 x 6 x 1 8 Pallet...

Страница 15: ...t Heater must always be vented to the outside See Vent Piping section pg 18 19 for details Minimum allowable space is shown on the nameplate OUTDOOR STACK INDOOR STACK NOTE The outdoor and indoor stac...

Страница 16: ...ane gas is MP a Millivolt heater using natural gas is MN Prefix C is for cast iron ASME headers P is for plastic polymer headers Suffix X is for cupro nickel tubing C is for copper tubing EXAMPLE P R4...

Страница 17: ...SME headers P is for plastic polymer headers Suffix X is for cupro nickel tubing C is for copper tubing EXAMPLE P R407A EN X Plastic headers 407 model size AFT natural gas cupro nickel For altitudes a...

Страница 18: ...ll have a minimum net free area as noted COMBUSTION AND VENTILATION AIR Indoor Units Only The heater must have both combustion and ventilation air Minimum requirements for net free air supply open ing...

Страница 19: ...ONS Gas piping must have a sediment trap ahead of the heater gas controls and a manual shut off valve locat ed outside the heater jacket All gas piping should be tested after installation in accordanc...

Страница 20: ...well VR8304 Heater Models 206 406 and 207 407 ELECTRONIC IGNITION GAS VALVES CONTINUED Gas Pressure Adjustment Robertshaw 7200 Heater Model 206 Robertshaw 7000 BDER Heater Models 266 336 Gas Pressure...

Страница 21: ...AFFLE Manufactured after 11 08 FLOW GPM PRESSURE DROP FT OF HEAD 206 207 266 267 336 337 406 407 20 4 0 25 4 0 4 6 30 4 0 5 2 35 4 0 5 8 5 2 40 4 6 5 8 5 2 5 2 50 4 6 6 3 6 9 6 9 60 4 6 6 9 6 9 6 9 70...

Страница 22: ...d scaling temper atures U G Plug Polymer Unitherm Governor Gasket POLYMER HEADERS STANDARD MODELS Before attaching the 2 inch unions to the inlet outlet header make sure the O rings are properly seate...

Страница 23: ...nd outlet pipes at the heater Outlet pipes should be slightly warmer than inlet and comfort able to the touch If pipe is hot close bypass if cold open bypass PRESSURE RELIEF VALVE INSTALLATION To conf...

Страница 24: ...at any water leaks will not damage the structure of adjacent area PVC pipe may be glued directly into header unions Standard models only CAUTION An additional source of heated water e g a solar system...

Страница 25: ...sheets Clean off tube sheet area where the gasket seats Also clean off the header and the gasket Apply a non petrole um based lubricant to the gasket such as AquaLube Re attach the headers to the oppo...

Страница 26: ...n the far left side of the heater 8 Re route all high voltage wires and ground wires through the left jacket side of heater 9 Re install P6 connector ground wires SPG transformer junction box front do...

Страница 27: ...RIC HEATER 120V LOW NOx HEATER SUPPLY SIDE SUPPLY SIDE RETURN or NEUTRAL RETURN or NEUTRAL HEATER 4 WIRES HEATER 7 WIRES GROUND L1 L1 HOT RED RED RED BLACK BLACK BLACK BLACK HOT BLACK GREEN GREEN GREE...

Страница 28: ...28 WIRING DIAGRAM MILLIVOLT MECHANICAL THERMOSTAT...

Страница 29: ...29 WIRING DIAGRAM ATMOSPHERIC...

Страница 30: ...30 WIRING DIAGRAM LO NOx...

Страница 31: ...eader HL1 High Limit HL2 High Limit Pressure Switch Temp Sensor Well Pilot Roll Out Switch Gas Valve Transformer Drain Plug Drain Plug Located in rear header Unitherm Governor Mounted On Top Of Header...

Страница 32: ...knob stop adjustment ring illustrated below is adjustable by loosening the set screw rotating the knob stop ring to the desired location and re tightening the set screw SPA TEMPERATURE RANGE POOL TEMP...

Страница 33: ...ry press the MODE and UP buttons simultaneously for 3 to 5 seconds The heater will continue to operate normal ly while in the Service Menu The first screen dis played is the Flame Strength indicator w...

Страница 34: ...displaying Celsius as well as Fahrenheit temperatures The UP or DOWN buttons will select Fahrenheit or Celsius on the temperature display Choose the desired temperature scale Spa Max Temp Spa Set Poi...

Страница 35: ...eplace board EEPROM Fault Memory fault reset set points replace board if fault does not clear Clock Fireman Sw Time clock fireman switch circuit is open Low Temp Lockout Water temperature below 36 F T...

Страница 36: ...e circuit created by the remote wiring Typically a remote does not supply power to the heater it only provides a switching function to turn the heater On or Off If your remote is supplying its own vol...

Страница 37: ...The actual setpoint will be con trolled by the remote control 4 Turn the mode button to OFF and remove power from the heater 5 On the Remote Interface Harness connect the BLUE wire to one side of the...

Страница 38: ...located below the level of the spa or pool it may be necessary to adjust the pressure switch to compen sate for the no flow static head If it is necessary to adjust the water pressure switch utilize...

Страница 39: ...e 5 Reverse above procedure to reinstall HIGH LIMIT REMOVAL 1 Shut off main electrical power switch to heater 2 Remove inlet outlet inspection panel 3 Remove defective high limit and replace with a ne...

Страница 40: ...er straight up using caution not to damage refractory 8 Reverse above procedure to reinstall Make sure the insulation strips are properly replaced on top of the refractory retainer TUBE CLEANING PROCE...

Страница 41: ...e made of the burners ELECTRICAL Be sure that electrical service to the heater has prop er overload fuse or circuit breaker protection wire size and connections which comply with all applicable codes...

Страница 42: ...Remove 2 screws that mount the pilot assembly to the burner tray 4 Pull the pilot assembly downwards and outwards 5 Reverse above procedure to reinstall COMBUSTION BLOWER REMOVAL 1 Remove the 2 screw...

Страница 43: ...ment replace Air starvation Refer to installation instructions Improper venting Follow recommended installation instructions Insects or debris clogging burner intake ports Clean burners Pilot outage o...

Страница 44: ...ilot burner does not light Light pilot If pilot burner goes out when main burner lights or when gas valve knob is released If burner does not remain lit attach millivolt meter and read pilot output If...

Страница 45: ...d pilot operator on gas control Check for 24 VAC across PV MV PV terminals on PC board If voltage is okay replace gas control if not replace PC board NOTE If PC board goes into lockout reset system Lo...

Страница 46: ...P1 Check resistance value of the thermister Reference to chart below Replace thermister if not within 10 of values shown below If okay replace Circuit Board Temp Degrees F 40 50 60 70 80 90 100 106 Re...

Страница 47: ...acement under standard company warranties must be properly tagged with a return parts tag completely filled in with the heater serial number model number etc and shipped to the Company freight prepaid...

Страница 48: ...V 14 M I S I3 S 2 S 5 HP 4 HP 7 HP 6 HP I2 S 6 HP I5 HM 3 HP 7 S 3 R 4 S 17 HM 11 S 4 C 9 M 8 S 13 M 12 M 3 S 4 B 2 B 5 M 5 B 1 B 1 G 1 J 4 S 5 S 6 S 14 M 1 R 2 R 2 J 7 HP 3 B 10 S 10 M 4 M 2 M 3 M 5...

Страница 49: ...V 9 M I S I3 S 2 S 5 HP 4 HP 7 HP 6 HP I2 S 6 HP I5 HM 3 HP 7 S 3 R 4 S 17 HM 11 S 4 C 6 M 8 S 8 M 7 M 3 S 3 B 4 B 1 G 10 S 1 B 2 B 2 M 3 J 10 M 6 B 5 B 7 C 1 J 4 S 5 S 6 S 9 M 1 R 2 R 2 J 13 M 4 V 12...

Страница 50: ...OPTIONAL POLYMER IN OUT HEADER AND ACCESSORIES 1 M 3 C 6 C 5 HM 17 HM 14 HM 13 HM 2 HM 4 HM 7 HM 3 HM 6 HM 2 S 9 S 4 S HONEYWELL IID ATMOSPHERIC PILOT 2 P 7 P 9 P 8 P 1 P 5 P 6 P 3 P 9 P HONEYWELL MIL...

Страница 51: ...4306F 004306F HP HEAT EXCHANGER POLYMER 1 HP Heat Exchange Assy Copper 010043F 010044F 010045F 010046F Heat Exchange Assy Cupro Nickel 010356F 010357F 010358F 010359F 2 HP Inlet Outlet Header Complete...

Страница 52: ...90F 9 M Control Bezel MV Includes Dial Decal 009489F 009489F 009489F 009489F 10 M Dial Decal MV 009858F 009858F 009858F 009858F 11 M Control Bezel Includes Switch Decal Units manufactured prior to 5 2...

Страница 53: ...505 009505 009505 009505 9 S High Limit Cover 010319F 010319F 010319F 010319F 10 S Base Heat Shield 010320F 010320F 010320F 010320F 11 S Up Front Control Panel Green 010321F 010322F 010323F 010324F Co...

Страница 54: ...12 HP Bypass Spring All Sizes Included 006718F 006718F 006718F 006718F 13 HP Unitherm Governor 006719F 006719F 006719F 006719F 14 HP Unitherm Governor Plug 006720F 006720F 006720F 006720F 15 HP Drain...

Страница 55: ...1926F 011926F 011926F 5 P Hi Tension Wire IID 010349F 010349F 010349F 010349F 6 P Adapter Nut Metric 011927F 011927F 011927F 011927F R REFRACTORY 1 R Refractory Common Left Right 010079F 010079F 01007...

Страница 56: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A...

Отзывы: