H. TAP OUTLET 

 

To prevent damage during transport the tap 
is  wrapped  and  placed  inside  the  unit 
enclosure  near  the  solenoid  valve  &  vent 
fittings. The  tap  is  connected  to  the  tap 
extension  by  a  chrome-plated  nut  and 
tightened using a 29 mm AF spanner. 

J. ELECTRICAL REQUIREMENTS: 

WARNING:

 

If this boiling water unit is to be installed in 
a  newly  constructed  building,  ensure  that 
all  electrical  tests  including  insulation 
tests  have  been  performed  prior  to 
plugging  in  and  switching  on  your  new 
Boiling Water Unit. Failure to do so could 
damage the electronics. 

 

• 220 –240 Volts AC, 50 Hz, Single Phase 
• 10 Amps on 3, 5, 7.5,10 & 15 litre models 
• 15 Amps on 25 litre model 
• 20 Amps on 40 litre model 

A  flexible  cord  complete  with  a  plug  is 
supplied  on  all  3,  5,  7.5,  10  and  15  Litre 
models. Do not loosen the cord grip or pull 
excess  cord  into  the  Lazer.  If  the  supply 
cord  of  this  unit  is  damaged,  it  must  be 
replaced  by  the  manufacturer  or  a 
qualified service person. 

The  25  and  40  litre  models  must  be 
installed  with  fixed  wiring.  A  means  of 
disconnection  from  all  active  (phase) 
conductors  of  the  power  supply  must  be 
incorporated 

during 

installation 

in 

accordance with the wiring rules. 

 

 

 

 

 

 

 

 

 

4. OPERATION 

 

When  the  installation  is  complete,  first 
turn  on  the  water  supply  before 
switching on the power.  
On  initial  start-up,  the  unit  automatically 
runs through a set-up cycle to detect the 
boiling  point  of  water  (calibration  cycle) 
and  during  this  cycle  steam  may 
discharge  from  the  vent  pipe  for  a  short 
time.    It  is  important  not  to  operate  the 
tap  during  the  set-up  cycle  because  it 
may  affect  the  operating  temperature  of 
the  unit.  After  the  boiling  point  is 
detected  the  unit  automatically  starts 
incremental filling.   
The unit is programmed to automatically 
operate 24 hours a day, 7 days a week. 
It is highly recommended for the user to 
program  the  timer  (if  the  unit  supplied 
has  one), as  this  will  increase  the  life  of 
the unit,  
and consume less power (see Section 5 
for how to program the timer).  
The  electronic  controller  constantly 
monitors  and  controls  the  water  level 
and  water  temperature  to  optimise  the 
boiling water delivery. 

 
 
 
 

Operation based on an inlet water 

temperature of 18ºC 

LAZER 
Size 
(Litre)

 

Calibration 

Cycle 

(min) 

Approx 

Recovery 

(Litres / Hour) 

Approx. Time 

to heat full 

Capacity (min) 

3.0  

22 

17.5 

12 

5.0  

 

21 

15 

7.5  

 

21 

22 

10  

 

21 

29 

15  

 

21 

40 

25  

 

33 

40 

40  

30 

41 

50 

5. 

5. 

Содержание Lazer Classic Series

Страница 1: ...OWNERS GUIDE INSTALLATION INSTRUCTIONS CLASSIC SERIES POWDER COATED Models 3 5 7 5 10 15 25 40 Litre STAINLESS STEEL Models 7 5 10 15 25 40 Litre IMPORTANT PLEASE LEAVE WITH THE OWNER Part No 316935A...

Страница 2: ...ap Outlet 5 J Electrical Requirements 5 4 OPERATION 5 MOUNTING DIMENSION SPECIFICATION FOR ALL MODELS drawing 6 DIMENSION SPECIFICATION FOR ALL MODELS drawing 7 5 FOR UNITS WITH A TIMER 8 A Setting Th...

Страница 3: ...te on the left hand side C MINIMUM CLEARANCES For ventilation reasons all units require a minimum clearance of 50mm on all sides For ease of servicing where there is sufficient space we recommend 300m...

Страница 4: ...ipe must discharge to waste at a point where no scald injury nuisance nor inconvenience is caused to people in the immediate vicinity WARNINGS Ensure the overflow vent line remains open because the La...

Страница 5: ...of the power supply must be incorporated during installation in accordance with the wiring rules 4 OPERATION When the installation is complete first turn on the water supply before switching on the po...

Страница 6: ...334 334 490 490 490 B mm 143 176 176 176 180 235 325 C mm 400 430 515 615 615 615 615 D mm 234 267 267 267 271 326 416 E mm 15 15 15 15 8 8 8 F mm 50 50 50 50 32 32 32 G mm 53 53 53 53 103 103 103 H m...

Страница 7: ...50 75 75 100 Maximum Water Pressure kPa 1000 1000 1000 1000 1000 1000 1000 Element Size kW 1 8 2 4 2 4 2 4 2 4 3 6 4 6 Classic Models Dimension 3 Litre 5 Litre 7 5 Litre 10 Litre 15 Litre 25 Litre 40...

Страница 8: ...Shows STD Pressing the UP button alternates the STD AUTO icons STD operation means that the unit operates 24 hours a day Auto mode reverts the unit to operate at the pre set times on the timer Press t...

Страница 9: ...Press the Accept button to confirm selection and the display reverts to the Filter menu F To Service Menu Select Appropriate Service Mode i Error Codes ii Boiling Temp iii Chiller Temp iv Calib Reset...

Страница 10: ...it to help determine the life of any filter attached to the unit To reset the filter the operator only has to push the Filter Reset button for 10 seconds C Power LED Red The red Power LED shows that t...

Страница 11: ...heating element is properly wired then check its resistance Replace if broken Electronic Controller failure Test the electronic controller Thermistor failure Replace the thermistor 3 The unit boils co...

Страница 12: ...the installed site will be for the account of the owner 4 The Warranty only applies to the Boiling Water Unit and therefore does not cover any plumbing or electrical parts supplied by the installer a...

Отзывы: