Installation
Thermostat Over
vie
w
Thermostat Setup
Ad
vanced
Installer Men
u
34
Installer’s Guide
Equipment User Men
us
Heat Pump User Menus (cont.)
Cool Setup
Parameter
Options
Comments
AC Profile
A, B, C, D
Selectable Airflow Profiles
(see Heat Pump Installer Guide)
Cool Air Adj % -10, 0, 10
Selectable Cooling Airflow Adjustments
On Demand
Dehum
On, Off
Select Blower Operation on based on humidity
Reset All Dflts
No, Yes
Resets the Heat Pump to the Factory Default
Configuration by selecting Yes
Heat Setup
Parameter
Options
Comments
HP Profile
A, B, C, D
Selectable Airflow Profiles (See Heat Pump
Installer Guide)
Heat Air Adj %
-10, 0, 10
Selectable Heat Pump Airflow Adjustments
Dfrost Cmpr Dly 0, 5
Selectable Compressor Delay during defrost
Reset All Dflts
No, Yes
Resets the Heat Pump to the Factory Default
Configuration by selecting Yes
HP Staging
(Multi-Stage
Units Only)
On, Off
For Multi-Stage Heat Pumps Factory Default is On.
This allows Low/High stages of capacities. To only
allow High capacity in Heat Pump Mode select Off