Compressor Control (K2)
• Sealed single pole compressor relay switch with optical feedback feature (arc
detection)
Thermostat Connector (E2)
•
R
– 24VAC from the indoor unit 24VAC transformer (40 VA minimum)
•
C
– 24VAC Common from the indoor unit 24VAC transformer
• 1-Data: System Communications Line 1
• 2-Data: System Communications Line 2
Low Volt Fuse
• If required replace with 3 A automotive ATC style blade fuse
Low Pressure Control (LPC Input)
• Low-pressure control is factory installed
• Low pressure control is an automatic resetting device
High Pressure Control (HPC Input)
• High-pressure control is factory installed
• High pressure control is an automatic resetting device
Ambient Temperature Sensor (included with all applications)
• Included with all applications
TEST and SW2 Buttons
• TEST and SW2 buttons used to enter Test and Fault Recall Mode
Memory Card
• The memory card stores all unit information.
• The unit information is called shared data.
• The shared data is all the information needed for proper unit operation.
FIGURE 6
COMFORT CONTROL
2
BOARD
COMPRESSOR
WIRING
CONNECTOR
O.D. FAN (OFM) RELAY
COMPRESSOR
CONTROL (K2)
ICC (INTEGRATED
COMPRESSOR CONTROL)
TEST BUTTON
7-SEGMENT LED
AMBIENT DEFROST
CONTROL
DEFROST SENSOR
SW2 BUTTON
RED LED (Y1)
LOW VOLT FUSE
THERMOSTAT
CONNECTION (E2)
LOW PRESSURE CONTROL INPUT
HIGH PRESSURE CONTROL INPUT
{
MEMORY CARD
LINE VOLTAGE
CONNECTION
19
C
O
M
F
O
R
T
C
O
N
T
R
O
L
2
S
Y
S
T
E
M
™
C
O
N
T
R
O
L
W
IR
IN
G
Содержание ASL-JEC Series
Страница 48: ...48 FIGURE 13 WIRING DIAGRAM FOR ASL 024JEC 036JEC 19 0 WIRING DIAGRAMS...
Страница 49: ...49 FIGURE 14 WIRING DIAGRAM FOR ASL 039JEC 048JEC 060JEC DUAL DRIVE...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52 CM 1108...