MAINTENANCE  

(by authorised person only)

 

Rheem  recommends  annual  inspections  and  if  required  servicing 
by  a  qualified  person  to  ensure  safety,  peak  performance, 
longevity and avoid potential loss of warranty of this appliance. 

ISOLATION OF THE WATER HEATER 

The water heater should be switched off for servicing or if it is not 
used for long periods of time (eg. vacation). 
Isolate the water heater according to following steps: 

 

Isolate/switch  off  the  electrical  power  supply  to  the 
appliance.

 

 

Close  the  cold  water  supply  stopcock  valve  at  the  inlet  of 
heater 

– refer Diagram 3.

 

 

TEMPERATURE AND PRESSURE RELIEF (TPR) VALVE 

 

It  is  recommended  that  routine  preventative  maintenance  is 
carried  out  at  least  once  every  6  months  to  remove  lime 
deposits  and  verify  that  the  valve  is  operating  correctly  and 
the  discharge  line  is  not  blocked.    Failure  of  routine 
inspection may result in the water heater exploding.   

 

Continuous leakage of water from the valve may indicate 
a problem with the water heater. 

 

To  manually  operate,  carefully  lift  and  release  the  lever 
handle on the TPR valve to ensure the valve operates freely 
and  allow  several  litres  of  water  to  flush  through  the 
discharge line.  Ensure the discharge water is directed to the 
floor  drain.    Avoid  any  contact  with  the  discharge  water  to 
avoid scalding. 

 

If there is no water flowing out, please contact a serviceman.

 

 

Damage  to  the  water  heater  due  to  blockage/restriction  at 
the overflow outlet will void the 

manufacturer’s warranty.

 

 
 
 

 

DRAINING THE HEATER AND TPR REPLACEMENT 
 

Warning!  Beware of high temperature water. 

 

First, disconnect all power to the water heater. 

 

Turn off the cold water supply to the heater. 

 

Release the pressure in the heater by carefully operating the 
TPR valve release lever/knob. 

 

Undo the cold water inlet union. Attach a hose to the heater 
side of the union. Drain the hose to waste. 

 

Operate  the  TPR  valve  release  lever/knob  allowing  air  into 
the heater and water to drain via the hose. 

 

Remove and replace the TPR valve 

– beware of hot water. 

 

To fill heater refer 

to instruction “Filling the Water Heater”. 

 

WATER QUALITY 

 

The vitreous enamel lined cylinder of the water heater is only 
covered  by  the  warranty  when  the  total  dissolved  solids 
(TDS)  content  in  the  water  is  less  than 600  mg/L  and black 
colour coded magnesium anode (supplied with this heater) is 
used.  

 

The use of an incorrect anode may shorten the life of the 
water heater cylinder. 

 

The anode installed in this water heater will slowly dissipate 
whilst protecting the cylinder. The life of the cylinder may be 
extended  by  replacing  the  anode.    For  all  water  supplies,  if 
the anode is not replaced during a major 5 year service then 
the  maximum  time  after  installation  when  the  anode  should 
be replaced for this water heater is 8 years. 

 

No  warranty  applies  to  the  corrosion  resistant  heating  unit, 
supplied with this heater, when the chloride concentration of 
the water supply exceeds 200ppm. 

WARRANTY CONDITIONS 

PLEASE CONTACT YOUR LOCAL DITRIBUTOR 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

COMMON FAULTS AND REMEDIES 

Fault 

Possible Causes 

Remedies 

No hot water flowing 
out 

1)  Cold water inlet supply to heater is closed. 
2)  Pipes are blocked 
3)  Water supply is cut off by Utility 

1)  Turn on the inlet tap 
2)  Dredge the pipe by plumbers 

Water temperature 
is not hot enough 

1)  Terminal block is damaged 
2)  Earth Leakage Circuit Breaker (ELCB) has operated 
3)  Element has failed 
4)  ECO has activated (Hi Limit) 
5)  Set temperature is too low 
6)  Thermostat is damaged 
7)  Water Heater is working 

1)  Call electrician 
2)  Call electrician 
3)  Call electrician 
4)  Call electrician 
5)  Raise the set temperature 
6)  Call electrician 
7)  Please wait for a while 

Abnormal noise is 
coming from the water 
heater and pipelines 

1)  Heating up noise 
2)  Abnormal sound in pipeline when mains pressure is 

not stable 

3)  Scaling on heater element 
4)  Water Hammer 

1)  Normal 
2)  Normal. Close the cold water inlet tap for a while. 
3)  Contact a serviceman 
4)  Contact a serviceman 

TPR Temperature and 
Pressure Relief Valve is 
discharging water 

1)  Expansion of water during heating up 
2)  Valve is blocked by foreign materials 
3)  Excessive cold water pressure 

1)  Normal 
2)  Operate valve lever to remove dirt deposit 
3)  Reduce incoming water pressure 

 

VN 093 00 02 - 09

 