SAFETY 

 

This appliance is not intended for use by persons (including 
children)  with  reduced  physical,  sensory  or  mental 
capabilities,  or  lack  of  experience  and  knowledge,  unless 
they  have  been  given  supervision  or  instruction  concerning 
the  safe  use  of  the  appliance  by  a  person  responsible  for 
their  safety.    Children  should  be  supervised  to  ensure  that 
they do not play with the appliance. 

 

CAUTION:  In  order  to  avoid  a  hazard  due  to  inadvertent 
resetting  of  the  thermal  cutout,  this  appliance  must  not  be 
supplied  through  an  external  switching  device,  such  as  a 
timer,  or  connected  to  a  circuit  that  is  regularly  switched  on 
and off by an appliance or utility. 

 

The  water  heater  must  have  provision  for  drainage  in  the 
event that the water heater leaks or connection pipes break. 

 

The water heater is rated 220-240V/50Hz AC, single phase. 

 

The installation of the Electrical power supply cable must be 
correctly sized  to  safely  carry  the  maximum current  draw of 
the  appliance.    Ensure  all  earth  wires  and  connections  are 
separated from the neutral circuit. 

 

Ensure  that  the  electrical  connections  are  undertaken  by  a 
qualified electrician complying with Local Code of Practice. 

 

Power  must  not  be  turned  on  until  the  water  heater  is  filled 
with  water.    Open  all  hot  water  taps/faucets  to  release 
trapped air until only water is discharged. 

 

Temperature  over  50°C  may  cause  scalding.    Please  mix 
cold  water  with  hot  water  to  obtain  the  right  bathing 
temperature. 

 

Please  operate  the  Temperature  and  Pressure  Relief  Valve 
(TPR) manually at least once every 6 months to remove lime 
deposits  and  verify  that  the  drain  pipe  from  the  valve  is  not 
blocked. 

 

Power  must  be  turned  off  before  any  service  and 
maintenance  work  can  commence.    All  work  must  be 
performed by a qualified technician. 

 

For  replacement  of  parts,  please  use  original  parts  from 
manufacturer.  Use of non-approved parts will result in a void 
the manufacturer’s warranty. 

 

Water  may  drip  from  the  discharge  pipe  of  the  TPR  valve 
during normal expansion.  The discharge pipe should be left 
open  to  the  atmosphere  preferably  150  mm  above  the 
nearest  floor  trap.    On  no  accounts  must  the  drain  pipe  be 
plugged.    Blockage  of  the  TPR  discharge  pipe  may  cause 
serious damage and 

will void the manufacturer’s warranty. 

Warning 

–  Scalds  Minimisation.    To  minimise  scalding, 

especially for those people in high risk categories ie. Young 
children,  people  with  incapacitating  medical  conditions, 
elderly people, etc, this unit must be installed in accordance 
with  all  local  and  government  regulations,  and  the  use  of 
secondary  devices  such  as  a  suitable  tempering  valve  or 
anti-scald water shut-off valve. (If a tempering valve is used, 
refer to its servicing instructions for periodic maintenance.) 

 

Hot water must be stored at a minimum of 60°C to inhibit the 
growth of Legionella bacteria. 

 

All  sanitary outlets used primarily for personal hygiene shall 
deliver hot water not exceeding: a). 45°C for early childhood 
centres, primary and secondary schools and nursing homes 
or similar facilities for young, aged, sick or disabled persons; 
and b). 50°C in all other buildings. 

 

INSTALLATION AND CONNECTION 

(by authorised person) 

 
CHOOSING WHERE TO INSTALL 

 

The water heater must be installed indoors. 

 

The wall must be strong enough to support the water heater 
filled  with  water  using  the  universal  mounting  brackets  and 
masonry anchors provided. 

 

The heater should be installed as near to the point of use as 
possible. 

 

Ensure  that  sufficient  and  safe  space  is  available  for 
servicing  of  the  water  heater  to  both  adjacent  wall  and/or 
ceiling  for  access  to  the  element,  sacrificial  anode  and 
Temperature and Pressure Relief Valve. 

 

Leave  adequate  clearance  beside  the  appliance  (preferably 
the  length  of  the  water  heater),  for  inspection  or  service  of 
the  anode  through  the  case  lid.    If  inadequate  room  is 
available  then  the  appliance  may  have  to  be  disconnected 
and removed for service. 

 

There  must  be  a  floor  trap  near  installation  point  for  safe 
discharge of the Temperature and Pressure Relief Valve. 

 

The  water  heater,  electrical  connections,  and  electric 
leakage protector should be protected against any contact or 
splashing water. 
 

INSTALLATION OF THE WATER HEATER 

 

Fasten  the  mounting  bracket to  the upper  holes  in  the  back 
of  Water  Heater  with  two  (2x)  M10  bolts  and  washers 
provided in the loose parts kit.

 

 

Fasten the plastic lower wall spacer to the lower holes in the 
back  of  Water  Heater  with  the  two  (2x)  self  tapping  screws 
provided.

 

 

Locate  the  drilling  position  for  the  masonry  anchor  bolts  on 
the  wall,  as  shown  in  Diagram  2.  The  holes  must  be  in  the 
same horizontal line.

 

 

Drill holes  in the  wall,  and  then  insert the  two  (2x)  masonry 
anchor bolts complete with nuts. 

 

 

Hang up the water heater on the wall and tighten the anchor 
bolts to the wall mounting bracket.

 

 

 

ITEM 

COMPONENT 

QTY 

Wall Mounting Bracket 

Flat Washer 

Hexagon Head Screw 

Masonry Anchor 

Lower Wall Spacer 

Self Tapping Screw 

 

Diagram 2. Mounting Instruction 

 

CONNECTION 

– PLUMBING 

 

Pipe Material : 

The  pipes  connecting  to  the  inlet  and  outlet  of  the  water 
heater  must  be  strong  enough  to  withstand  water  pressure 
up  to  1.40  MPa

.  The  storage  water  heater  must  be 

permanently  connected  to  the  water  mains,  hose  set  is 
not recommended to be used. 

 

Pipe Size : 

¾”  (20mm)  OD  copper  pipes  are  to  be  used  for  cold  water 
inlet and hot water outlet 

– refer to Diagram 3. 

It is the responsibility of the installer to ensure all pipework & 
fittings are correctly lagged and do not leak. 

 

Connection : 
Water connections are located at the side of the heater. Heat 
must not  be applied  at these  connections as  it can  damage 
the internal  water  tubes  of the appliance 

– refer to Diagram 

4

Both  the  inlet  and  outlet  water  connections  are  located  at  the 
side of the water heater, with the upper connection being outlet 
and lower connection being inlet. The cold water tap is fitted to 
the inlet as shown in Diagram 3. As the temperature is high at 
the  outlet,  a  mixing  valve  which  mixes  hot  water  with  cold 
water is suggested to be fitted. If the outlet tap is not close to 
the  water  heater,  thermal  insulation  material  is  recommended 
to insulate the hot water pipe in order to reduce heat loss. 

 