Installing the water heater.

This water heater must be installed in accordance with these instructions, local codes, utility company
requirements, and/or in the absence of local codes, use the latest edition of the American National
Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,
400 N. Capitol Street NW, Washington, DC  20001 as ANSI standard Z223.1 or National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269 as booklet NFPA 54.

Location

The water heater should not be located
in an area where leakage from the tank
or connections will result in damage to
the area adjacent to the heater or to
lower floors of the structure. 

When such areas cannot be avoided it is
recommended that a suitable catch pan,
adequately drained, must be installed
under the water heater.

The pan must not restrict air flow to the
combustion air inlet openings
(perforation openings) located around
the lower perimeter of the water heater.  

Catch pan kits are available from the store
where the water heater was purchased, or
any water heater distributor.

Make certain the floor underneath the
water heater is strong enough to
sufficiently support the weight of the
water heater once it is filled with water.

A gas fired water heater or any other
appliance should not be installed 
in a space where liquids which give off
flammable vapors are to be used or stored.
Such liquids include gasoline, LP gas
(butane or propane), paint or adhesives
and their thinners, solvents or removers.

When installed in a closet, DO NOT
block or obstruct any of the combustion
air inlet openings located around the
perimeter of the water heater.   A
minimum of 1” is required between
these combustion air inlet openings and
any obstruction.

Because of natural air movement in a
room or other enclosed space, flammable
vapors can be carried some distance from
where liquids which give off flammable
vapors are to be used or stored. The open
flame of the water heater’s pilot or main
burner can ignite these vapors and create a

shut down condition of the water heater
which will not allow the water heater to
ignite until examined by a Qualified
Service Technician.

The water heater must be located so it is
not subject to physical damage, for example,

by moving vehicles, area flooding, etc. 

If local codes require the use of a stand kit
to raise the water heater 18” above the
floor, please contact the store where the
water heater was purchased, or any water
heater distributor. These kits must comply
with local codes.

The water heater should be installed as
close as practical to the gas vent or
chimney. 

Long hot water lines should be insulated
to conserve water and energy. 

The water heater and water lines should
be protected from exposure 
to freezing temperatures.

Do not 

install the water heater in

bathrooms, bedrooms, any occupied
rooms normally kept closed, or in
unprotected outdoor areas.

Minimum clearance from combustible
construction: 

If the clearances stated on the
Instruction/Warning Label, located on
the front of the heater differ, install the
water heater according to the clearances
stated on the label.

If the water heater is installed in an
alcove or closet, the entire floor must
be covered by a wood or metal panel.
A minimum of 24” clearance from the
front and top should be available for
adequate inspection and servicing.

The water heater may be installed on
combustible floors, but not directly on
carpeting. If the water heater must be
installed on carpeting, place a metal or
wood panel beneath the water heater,
extending beyond its full width and
depth at least 3” in all directions.

Combustion Air Inlet
 Openings

The auxiliary catch pan
installation MUST conform 
to local codes.

Max.

2

Diameter of

water heater
plus 2” min.

WARNING: Combustible

construction refers to
adjacent walls and ceilings
and should not be confused
with combustible or
flammable products and
materials. Combustible
and/or flammable products
and materials should never
be stored in the vicinity of
this or any gas appliance.

!

Combustion Air Inlet

Openings

Location

Front

Sides

Rear

Top

Alcove

3”

(7.6 cm)

0”

(0 cm)

0”

(0 cm)

12”

(30.5 cm)

Closet

3”

(7.6 cm)

1”

(2.5 cm)

0”

(0 cm)

12”

(30.5 cm)

Rear

Sides

Front Open

Sides

Front Enclosed

Top View Closet

Top View Alcove

Rear

7

Содержание 22V40F1

Страница 1: ...r the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater Thi...

Страница 2: ...model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty...

Страница 3: ...nt system for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding vent system inspection DANGE...

Страница 4: ...r temperature for each mark on the Gas Control Thermostat Temperature Dial DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause sever...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...RMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damag...

Страница 7: ...nd create a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subje...

Страница 8: ...located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal duc...

Страница 9: ...relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor wa...

Страница 10: ...e end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To...

Страница 11: ...r LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi rigid o...

Страница 12: ...nergy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such un...

Страница 13: ...ter heater jacket DON T remove the Burner Access Door unless absolutely necessary This should only be done by a qualified service technician A new burner access door gasket must be installed on any bu...

Страница 14: ...tion air inlet openings observed see page 7 Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Gas line equipped with shut off...

Страница 15: ...xisting heating unit or components of a heating system that have previously been used with a non drinking water system Toxic chemicals such as those used for boiler treatment may be present and will c...

Страница 16: ...and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injur...

Страница 17: ...more details The chart below may be used as a guide in determining the proper water temperature for your home Safety Precautions Do turn off manual gas shut off valve if water heater has been subject...

Страница 18: ...r that hotter water increases the risk of scald injury Also always supervise young children or others who are incapacitated The gas control thermostat is constructed with a built in safety shut off de...

Страница 19: ...ated solids can prevent the gas control thermostat sensors from accurately reading the water temperature the water at the fixture can be hotter than the gas control thermostat dial setting It is sugge...

Страница 20: ...r cleaning remove the burner from the water heater A vacuum cleaner can be used on the burner and floor shield inside the water heater The burner can also be cleaned by scrubbing with mild detergent P...

Страница 21: ...vice technician Pilot burner tube pinched or The pilot burner should be cleaned repaired or clogged replaced by a qualified service technician Gas Cock Knob not See the Lighting The Water Heater secti...

Страница 22: ...hting The Water Heater section of this manual The gas control thermostat See the Water Temperature Setting of The Water may be set too low Heater section of this manual Leaking or open hot Make sure a...

Страница 23: ...s vent connectors or other safety devices Refer repairs to qualified service personnel Draft hood Temperature and pressure relief valve Burner supply tube Flue baffle and hanger Anode rod Heat Trap He...

Страница 24: ...Drive East Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following information will be requested a Model and serial number of the water heater as shown on the...