Rheem 22V40F1 Скачать руководство пользователя страница 20

20

Venting System Inspection

The water heater’s internal flue must be
inspected annually to be certain it is clean
by removing the draft hood and flue
baffle.

When reinstalling the flue baffle make
certain it is hung securely by its hanger at
the top of the flue way.

Reinstall the draft hood.

Inspect the gas venting system and the
chimney.

Make certain the vent connector from the
draft hood to the chimney is properly
positioned and securely attached.

If after inspection of the vent system 
you found soot or deterioration; 
call the local gas utility to correct the
problem and clean the flue, or replace the
flue, flue baffle, and venting system
before resuming operation of the water
heater.

Test for spillage at the draft hood relief
opening after 5 minutes of burner
operation.  Use a flame of a match or
candle or smoke.

Burner Inspection

Visually inspect the pilot burner and main
burners annually.

Through the sight glass, inspect the pilot
burner flame with the main burner off and
inspect the main burner while firing.

If any unusual burner operation is noted,
the water heater should be shut off until
qualified service assistance can be
obtained.

CAUTION: For your safety, cleaning of

the burner must be performed only by
qualified service personnel.  The burner
chamber is a sealed area.  If the burner
access door is removed, the burner access
door gasket must be replaced.

For cleaning, remove the burner from the
water heater. A vacuum cleaner can be
used on the burner and floor shield inside
the water heater.The burner can also be
cleaned by scrubbing with mild detergent.

!

Proper burner and pilot burner
pattern.

Care and cleaning of the water heater.

Vacation and Extended Shut-Down

If the water heater is to remain idle for an
extended period of time, the power and
water to the appliance should be turned off
to conserve energy and prevent a build-up
of dangerous hydrogen gas.

The water heater and piping should be
drained if they might be subjected to
freezing temperatures.

After a long shut-down period, the water
heater’s operation and controls should be
checked by qualified service personnel.
Make certain the water heater is
completely filled again before placing it 
in operation.

NOTICE: Refer to the
Hydrogen Gas Caution in the
Operating Instructions.

Anode Rod

This water heater is equipped with an
anode rod designed to prolong the life of
the glass lined tank. The anode rod is
slowly consumed, thereby eliminating or
minimizing corrosion of the glass lined
tank. 

Water sometimes contains a high sulfate
and/or mineral content and together with
cathodic protection process can produce a
hydrogen sulfide, or rotten egg odor in the
heated water. Chlorination of the water
supply should minimize the problem.

NOTICE: Do not remove 
the anode rod from the water
heater’s tank, except for
inspection and/or replacement,
as operation with the anode
rod removed will greatly
shorten the life of the glass
lined tank and will exclude
warranty coverage.

Содержание 22V40F1

Страница 1: ...r the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater Thi...

Страница 2: ...model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty...

Страница 3: ...nt system for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding vent system inspection DANGE...

Страница 4: ...r temperature for each mark on the Gas Control Thermostat Temperature Dial DANGER Hotter water increases the potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause sever...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...RMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damag...

Страница 7: ...nd create a shut down condition of the water heater which will not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subje...

Страница 8: ...located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal duc...

Страница 9: ...relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor wa...

Страница 10: ...e end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To...

Страница 11: ...r LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi rigid o...

Страница 12: ...nergy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such un...

Страница 13: ...ter heater jacket DON T remove the Burner Access Door unless absolutely necessary This should only be done by a qualified service technician A new burner access door gasket must be installed on any bu...

Страница 14: ...tion air inlet openings observed see page 7 Water heater completely filled with water Air purged from water heater and piping Water connections tight and free of leaks Gas line equipped with shut off...

Страница 15: ...xisting heating unit or components of a heating system that have previously been used with a non drinking water system Toxic chemicals such as those used for boiler treatment may be present and will c...

Страница 16: ...and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injur...

Страница 17: ...more details The chart below may be used as a guide in determining the proper water temperature for your home Safety Precautions Do turn off manual gas shut off valve if water heater has been subject...

Страница 18: ...r that hotter water increases the risk of scald injury Also always supervise young children or others who are incapacitated The gas control thermostat is constructed with a built in safety shut off de...

Страница 19: ...ated solids can prevent the gas control thermostat sensors from accurately reading the water temperature the water at the fixture can be hotter than the gas control thermostat dial setting It is sugge...

Страница 20: ...r cleaning remove the burner from the water heater A vacuum cleaner can be used on the burner and floor shield inside the water heater The burner can also be cleaned by scrubbing with mild detergent P...

Страница 21: ...vice technician Pilot burner tube pinched or The pilot burner should be cleaned repaired or clogged replaced by a qualified service technician Gas Cock Knob not See the Lighting The Water Heater secti...

Страница 22: ...hting The Water Heater section of this manual The gas control thermostat See the Water Temperature Setting of The Water may be set too low Heater section of this manual Leaking or open hot Make sure a...

Страница 23: ...s vent connectors or other safety devices Refer repairs to qualified service personnel Draft hood Temperature and pressure relief valve Burner supply tube Flue baffle and hanger Anode rod Heat Trap He...

Страница 24: ...Drive East Montgomery Alabama 36109 1413 Phone 1 800 432 8373 When contacting the manufacturer the following information will be requested a Model and serial number of the water heater as shown on the...

Отзывы: