1.5.3 Further Installation Details
•
Pipe the condensate drain to within 1" of a drain, or connect it to a condensate
pump.
•
Slope the drainage line down to the drain at a pitch of 1/4" per foot, so that the
condensate runs towards the drain.
•
Check the condensate trap every 2 months, and clean and refill as necessary.
T
Tankless
Water Heater
Figure 22: Condensate trap drainage
DANGER
The water in the condensate
neutralizer can cause severe
burns to the skin. Use extreme
caution when servicing the
condensate neutralizer. Wear
protective gloves and eyewear.
CAUTION
When a condensate
neutralization package
is installed, the pH of the
condensate discharge must
be measured on a regular
schedule to ensure the
neutralizing agent is active
and effective.
WARNING
If condensates are to be
discharged into building drain
piping materials that are subject
to corrosion, a neutralization
package must be used.
Tankless
Water Heater
Figure 23: Condensate neutralization tank