05.01. general
information
05.02. selection keyboard
05.03. display
05.04. dispenser
05.05. door lock
05.06. drip tray
05.07. electric connection
05.08. power on switch
05.09. fuses
05.10. water drain plug
05.11. water inlet
solenoid valve
05.12. door switch
the Rhea
Cino XS grande PRO and PRO VHO
vending machine is
a machine explicitly designed for being easily used by all users
since no specific competence is required in preparing drinks;
the function consists in dispensing drinks by mixing food products
and water at a proper temperature; the correct operation of the
vending machine occurs in closed rooms in normal environmental
conditions and at a room temperature between 5 °C and 35°C, the
relative humidity below 80%;
use only specific ingredients for vending machines;
dispense by briefly pressing a key of the selection keyboard
(see 05.02.); make sure that the cup has been properly positioned
at the dispensing station, if necessary by using the flap support for
caps (see 03.07.);
after having closed the door, press the buttons to dispense; the
button will turn on during the dispensing cycle; keys will assume
various functions in the programming mode (see 09.) and enable
the user to modify the machine parameters; keys are numbered
progressively from the top: 1, 2, … and from the left;
the display messages inform users and operators about the
operation state of the vending machine;
the
Cino XS grande PRO and PRO VHO
vending machine has got
a fixed drink dispenser on the cup support surface;
the door is closed by means of a lock; the key is mapped and
numbered for identification;
it collects possible residual drops from the dispenser and, if
necessary, the waste water in excess from the boiler; it is slided at
the bottom of the machine case, in the front, and it is composed by
a covering drawer and a grilled cover that can be washed by
running water; an electric contact is intended to control the filling
level (see 11. and 13.03.);
a three-terminal socket is arranged at the back of the case for the
connection of the mains cable;
to power on and off the machine;
installed on the mains power supply (see 03.10.); fuses must be
necessarily replaced by specialised technical personnel only;
from where to let the silicone tube from the air break come out for
emptying;
the water inlet solenoid valve has got an anti-flood safety device
intended to stop the water inlet in case of failures; to its electrical
pins can be connected in parallel an any submersible pump (see
03.03.);
to power off the machine when the door is open;
attention
some parts remain anyway network-connected
act extremely carefully;
use the service key to supply the vending machine if it is necessary
to activate the machine when the door is open;
the key is housed in the cover;
03
02
1
2
3
4
5
6
7
8
9
10
04
05
06
08
09
07
11
12
10
MAN2100160 rel. 00 dated 05.11.2013 page no. 16 of 53 pages
www.rheavendors.com tel: 0039 02 966 551 fax: 0039 02 96 55 086 e mail: [email protected]
exclusive property of rheavendors group
Cino XS grande PRO and PRO VHO
by