RH TOLUCA 42100167 Скачать руководство пользователя страница 6

TOLUCA FIRE TABLE OWNER’S MANUAL

  

11

  

CONNECTION FOR NATURAL GAS

The flex line that runs from the gas valve to the 
burner has been connected at the factory. You  
will only need to connect the natural gas line from 
the gas valve to the gas source, as shown in the 

Figure E.

Perform a leak test before you replace the burner 
plate.

 (See below.)

Connect to the gas source.

Perform a leak test at least once a year whether the 
gas supply cylinder has been disconnected or not. 
In addition, whenever the gas cylinder is connected 
to the regulator or whenever any part of the gas 
system is disconnected or replaced, perform a  
leak test.

As a safety precaution, remember to always leak 
test your fire table outdoors in a well-ventilated area. 
Never smoke or permit sources of ignition in the 
area while doing a leak test. Do not use a flame, such 
as a lighted match to test for leaks. Use a solution of 
soapy water.

 

1.   Prepare a leak testing solution of 

soapy water by mixing in a spray 
bottle one part liquid soap to one 
part water.

 

2.   Make sure all the control knobs are in 

the 

OFF

 position.

 

3.   Turn on the gas.

 

4.   Apply the leak-testing solution 

by spraying it on joints of the gas 
delivery system. Blowing bubbles 
in the soap solution indicates that a 
leak is present.

 

5.    Stop a leak by tightening the loose 

joint or by replacing the faulty 
part with a replacement part 
recommended by the manufacturer. 
Do not attempt to repair the 
cylinder valve if it is damaged. 
The cylinder must be replaced.

 

6.   Turn the control knob back to the full 

OFF

 position.

If you are unable to stop a leak:

 

7.   Turn the control knob back to the full 

OFF

 position.

 

8.    Shut off the gas supply to the fire 

table and release pressure in the 
hose and manifold.

 

9.   On propane systems, remove the 

cylinder from the fire table.

 

10.   Call an authorized gas appliance 

service technician or an liquid 
propane gas dealer.

Do not use the appliance until the leak is corrected.

PERFORM A LEAK TEST

NG FLEX LINE WITH  

½" ADAPTER

After you have completed all plumbing installation, 
you can fill the fire table with the decorative filler 
material provided.

Type of filler placement, such as lava rock, decorative 
stone or glass, is entirely your choice according to 
your preferences, but it needs to be rated for use 
with fire. It will not affect the operation of the fire 
table in any way. You can place the filler material 
on the burner, but no higher than 1" thick. Excessive 
filler material may impede gas flow and cause gas 
build-up and potentially cause an explosion.

PLACE DECORATIVE STONE IN FIRE TABLE

SET-UP 

CONTINUED

Содержание TOLUCA 42100167

Страница 1: ...1 TOLUCA FIRE TABLES MODELS 42100167 42100171 42100189 42100190 OWNER S MANUAL...

Страница 2: ...CSA Standards The following information regarding safe operation and maintenance of this appliance is a result of the tests performed by RADCO and certified by ICC ES SAFETY INSTRUCTIONS 4 GAS REQUIRE...

Страница 3: ...exactly may result in fire or explosion causing property damage personal injury or loss of life We recommend installation is completed by professionals that are locally licensed by the authority havi...

Страница 4: ...line pressure for propane is 11 W C Pressure Regulator The unit must be used with the supplied gas pressure regulator and hose assembly The regulator will control and maintain a uniform gas pressure...

Страница 5: ...cm measured from bottom of fire table to flooring surface for ventilation VENTILATION Fresh air must be able to pass though installed vents to safeguard against residual gas accumulation Failure to al...

Страница 6: ...stem Blowing bubbles in the soap solution indicates that a leak is present 5 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufa...

Страница 7: ...hear gas flowing use either a long stem wooden match or a butane fireplace lighter to place a flame near the burner 4 If the burner does not light does not stay lit or the flame is very low shut off...

Страница 8: ...all This limited warranty applies only to fire tables normally used for personal family or household purposes and specifically excludes rental or commercial applications This warranty is non transfera...

Страница 9: ...52 2 2 ITEM NO PART QTY 1 51 1 Burner 1 2 63 11 Burner Plate 1 3 Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 72 20 15 Fire Bowl 1 Gas Valve Key 1 ITE...

Страница 10: ...MODEL ONLY 8 Propane Hose 10 Length 1 9 70 000btu LP Regulator 1 10 Quick Connect Fitting 1 NG MODEL ONLY 11 70 000btu NG Regulator 1 12 Street 90 1 DIMENSIONS PARTS LIST NG MODEL LP MODEL 24 24 1 Le...

Страница 11: ...TOLUCA FIRE TABLE OWNER S MANUAL 030617 2017 RH and RESTORATION HARDWARE INC All rights reserved Other company names mention herein are trademarks of their respective companies...