![RH TOLUCA 42100167 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/rh/toluca-42100167/toluca-42100167_owners-manual_1450910006.webp)
TOLUCA FIRE TABLE OWNER’S MANUAL
11
CONNECTION FOR NATURAL GAS
The flex line that runs from the gas valve to the
burner has been connected at the factory. You
will only need to connect the natural gas line from
the gas valve to the gas source, as shown in the
Figure E.
Perform a leak test before you replace the burner
plate.
(See below.)
Connect to the gas source.
Perform a leak test at least once a year whether the
gas supply cylinder has been disconnected or not.
In addition, whenever the gas cylinder is connected
to the regulator or whenever any part of the gas
system is disconnected or replaced, perform a
leak test.
As a safety precaution, remember to always leak
test your fire table outdoors in a well-ventilated area.
Never smoke or permit sources of ignition in the
area while doing a leak test. Do not use a flame, such
as a lighted match to test for leaks. Use a solution of
soapy water.
1. Prepare a leak testing solution of
soapy water by mixing in a spray
bottle one part liquid soap to one
part water.
2. Make sure all the control knobs are in
the
OFF
position.
3. Turn on the gas.
4. Apply the leak-testing solution
by spraying it on joints of the gas
delivery system. Blowing bubbles
in the soap solution indicates that a
leak is present.
5. Stop a leak by tightening the loose
joint or by replacing the faulty
part with a replacement part
recommended by the manufacturer.
Do not attempt to repair the
cylinder valve if it is damaged.
The cylinder must be replaced.
6. Turn the control knob back to the full
OFF
position.
If you are unable to stop a leak:
7. Turn the control knob back to the full
OFF
position.
8. Shut off the gas supply to the fire
table and release pressure in the
hose and manifold.
9. On propane systems, remove the
cylinder from the fire table.
10. Call an authorized gas appliance
service technician or an liquid
propane gas dealer.
Do not use the appliance until the leak is corrected.
PERFORM A LEAK TEST
NG FLEX LINE WITH
½" ADAPTER
After you have completed all plumbing installation,
you can fill the fire table with the decorative filler
material provided.
Type of filler placement, such as lava rock, decorative
stone or glass, is entirely your choice according to
your preferences, but it needs to be rated for use
with fire. It will not affect the operation of the fire
table in any way. You can place the filler material
on the burner, but no higher than 1" thick. Excessive
filler material may impede gas flow and cause gas
build-up and potentially cause an explosion.
PLACE DECORATIVE STONE IN FIRE TABLE
SET-UP
CONTINUED