Perform a leak test at least once a year whether the 
gas supply cylinder has been disconnected or not. 
In addition, whenever the gas cylinder is connected 
to the regulator or any part of the gas system is 
disconnected or replaced, perform a leak test.

As a safety precaution, remember to always test for 
leaks outdoors in a well-ventilated area.

Never smoke or permit sources of ignition in the 
area while doing a leak test. Do not use a flame, such 
as a lit match, to test for leaks.

 

1.   Prepare a leak testing solution by 

mixing equal amounts of liquid soap 
and water in a spray bottle.

 

2.   Make sure all the control knobs are  

in the 

OFF

 position.

 

3.   Turn on the gas.

 

4.   Apply the leak-testing solution by 

spraying it on the joints of the gas 
delivery system. The appearance 
of bubbles in the soap solution 
indicates that a leak is present.

 

5.   Stop the leak by tightening the loose 

joint or, if caused by a faulty part, 
replace with a part recommended 
by the manufacturer. If the cylinder 
valve is damaged, do not attempt  
to repair it, as it must be replaced.

 

6.   Turn the control knob back to the  

full 

OFF

 position.

If you are unable to stop a leak:

 

7.   Turn the control knob back to the  

full 

OFF

 position.

 

8.   Shut off the gas supply to the fire 

table and release the pressure from 
the hose and the manifold.

 

9.   Remove the propane gas cylinder 

from the fire table.

 

10.   Call an authorized gas appliance 

service technician or a liquid propane 
gas dealer.

Do not use the appliance until the leak is fixed.

PERFORM A LEAK TEST

After you have completed the plumbing installation, 
you can fill the fire table with the decorative filler 
material provided.

The type of filler placement, such as lava rock, 
decorative stone or glass, is entirely your choice, but 
it must be rated for use with fire. It will not affect 
the operation of the fire table in any way. The filler 
material may be placed on the burner, but must 
not exceed 1" in height. Excessive filler material can 
impede gas flow and cause a build-up, potentially 
resulting in an explosion.

PLACE DECORATIVE STONE IN FIRE TABLE

SET-UP 

CONTINUED

(External View)

Содержание 42100332, 42100335, 42100334

Страница 1: ...1 1 OWNER S MANUAL MODELS 42100332 42100335 42100334 42100337 90100030 90100026 90100022 42100167 42100190 IXTAPA FIRE TABLES...

Страница 2: ...adian and USA Markets CSA Standards The following information regarding safe operation and maintenance of this appliance is a result of the tests performed by RADCO and certified by ICC ES SAFETY INST...

Страница 3: ...ersonal injury as will the installation of parts other than those specified for use with this appliance Only use the fuel type specified for this fire table Verify the correct fuel type and pressure b...

Страница 4: ...ortation DOT Specifications for LP Gas Cylinders or the Standard for Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission CAN CSA B339 as applicable Manifold Pressure For p...

Страница 5: ...below Set up of your Ixtapa Fire Table consists of 4 easy steps 1 Place Fire Table in Desired Location 2 Connect Gas Line 3 Perform a Leak Test 4 Place Decorative Stone in Fire Table This appliance w...

Страница 6: ...a part recommended by the manufacturer If the cylinder valve is damaged do not attempt to repair it as it must be replaced 6 Turn the control knob back to the full OFF position If you are unable to st...

Страница 7: ...hter to place a flame near the burner 4 If the burner does not light or stay lit or if the flame is very low shut off the gas supply and wait five minutes to allow all fumes to clear Start again from...

Страница 8: ...mily or household purposes and specifically excludes rental or commercial applications This warranty is non transferable Decorative stones and decorative glass are not covered by this warranty This wa...

Страница 9: ...SIONS PARTS LIST ITEM NO PART QTY 1 15 17 Burner 1 2 39 Diameter Burner Plate 1 3 Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propa...

Страница 10: ...oupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propane Hose 10 Length 1 9 65 000btu LP Regulator 1 10 Quick Connect Fitting 1 36 Round...

Страница 11: ...3 Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propane Hose 10 Length 1 9 65 000btu LP Regulator 1 10 Quick Connect Fitting 1 48 Squ...

Страница 12: ...Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propane Hose 10 Length 1 9 65 000btu LP Regulator 1 10 Quick Connect Fitting 1 72 36 F...

Страница 13: ...Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propane Hose 10 Length 1 9 65 000btu LP Regulator 1 10 Quick Connect Fitting 1 56 36 F...

Страница 14: ...3 Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 ITEM NO PART QTY 8 Propane Hose 10 Length 1 9 65 000btu LP Regulator 1 10 Quick Connect Fitting 1 72 20...

Страница 15: ...uick Connect Fitting 1 24 16 Fire Table 1 Gas Valve Key 1 Lava Rock 1 Vinyl Cover 1 NG MODEL LP MODEL 24 24 1 Leveling Bolt 1 24 16 4 4 16 Burner Support 16 4 10 14 5 24 24 1 Leveling Bolt 1 24 16 4 4...

Страница 16: ...IXTAPA FIRE TABLE OWNER S MANUAL 31 THESE PAGES INTENTIONALLY LEFT BLANK...

Страница 17: ...IXTAPA FIRE TABLE OWNER S MANUAL 2022 RH and RESTORATION HARDWARE INC All rights reserved Other company names mention herein are trademarks of their respective companies 021622...

Отзывы: