background image

 
13. 

 

Do not adjust the HydraPak while it is running.

 

 
14. 

 

Never adjust or service the associated hydraulic equipment during operation or while connected to the HydraPak.  

 
15. 

 

Know how to stop the HydraPak quickly in case of emergency.

 

 
16. 

 

Allow engine to cool two minutes before refueling. 

 
17. 

 

Never disconnect hydraulic hoses or fittings while the HydraPak is running. 

 
18. 

 

At end of operation, secure the HydraPak and the associated hydraulic equipment to prevent unauthorized use.  Never

 

assume you will find the equipment in the same condition in which you left it.

 

 

19. 

 

Only trained personnel are authorized to do repairs. 

 
20. 

 

Do not use the HydraPak or associated hydraulic equipment when you are tired or fatigued. 

 
21. 

 

Do not operate the HydraPak or associated hydraulic equipment when under the influence of drugs, alcohol, or 
medication. 

 
 
 
 
 
 
 
 

 

 

 

 

Содержание HYDRAPAK HV1855C

Страница 1: ...HV1855C HYDRAPAK INSTRUCTIONS REIMANN GEORGER CORPORATION CONSTRUCTION PRODUCTS BUFFALO NY P N 6122035 11 25 13...

Страница 2: ...ne 5 3 1 2 Checking the Hydraulic System 5 3 2 Starting and Operating the HydraPak 6 3 3 Stopping the HydraPak 7 4 INSPECTION AND MAINTENANCE 8 4 1 General Maintenance Rules 8 4 2 Hydraulic System Ins...

Страница 3: ...ate this HydraPak or the associated hydraulic tools It is recommended that this checklist be maintained as a permanent record Insure construction area is secured from all unauthorized personnel All cr...

Страница 4: ...only accidents 1 3 HYDRAPAK SAFETY LABELS These labels warn you of potential hazards that could cause injury Read them carefully If a label comes off or becomes illegible contact Reimann Georger Corpo...

Страница 5: ...oses or fittings while the HydraPak is running 18 At end of operation secure the HydraPak and the associated hydraulic equipment to prevent unauthorized use Never assume you will find the equipment in...

Страница 6: ...er Breather 100 mesh Electrical Charging System 12 14V 16 AMP regulated to battery Battery Type 12V 15 Plate 400 CCA Fuse Automotive Ignition 5 AMP Blade Type Fan 25 AMP Standard Features Hour meter E...

Страница 7: ...dering spare parts or requesting assistance in service The HydraPak has a product nameplate that shows the model and serial numbers as shown in Figure 2 1 Record the model and serial numbers for futur...

Страница 8: ...el comes off or becomes hard to read contact Reimann Georger Corporation for replacement information 4 Construction area is to be kept clear of unauthorized personnel Place barricades or secure the ar...

Страница 9: ...cted return tank line from the HydraPak tank port to the return port of the hydraulic tool c Then connect the pressure line from the hydraulic tool pressure port to the pressure port on the HydraPak w...

Страница 10: ...PPING THE HYDRAPAK At the end of operation secure the equipment to prevent unauthorized use Never assume you will find the equipment in the same condition that you left it Proceed as follows 1 Let the...

Страница 11: ...WIRE FROM THE BATTERY TERMINAL WARNING DO NOT ADJUST OR REMOVE HYDRAULIC COMPONENTS LINES OR FITTINGS WHILE THE HYDRAPAK IS RUNNING OR WHENEVER THE HYDRAULIC FLUID IS HOT WARNING LIQUID UNDER HIGH PRE...

Страница 12: ...D MAINTENANCE 1 The following rules must be observed when doing engine maintenance a Do not check for a spark with the spark plug removed Use an approved tester b Do not crank the engine with the spar...

Страница 13: ...eplace engine oil filter 100 hrs Check clean and replace spark plug 100 hrs Have cylinder head removed and cleaned leaded fuel 100 hrs Have cylinder head removed and cleaned unleaded fuel 200 hrs Repl...

Страница 14: ...aulic tool being used check hydraulic tool requirement c Air in fluid inspect for oil leaks and repair to correct d No work being done open center tools only produce pressure under load No hydraulic o...

Страница 15: ...sure requirement Extension hoses too long a Hoses over 50 feet long add sufficient friction to the hydraulic system to slow down the hydraulic tool slightly b Where possible use as few quick disconnec...

Страница 16: ...n suction line Improper type of hydraulic oil as an original equipment manufacturer RGC uses a Grade ISO VG 32 hydraulic oil If you have any questions concerning the type of oil you should use for you...

Страница 17: ...in the engine manual Auto idle override switch has been left in bypass push switch down to put engine in auto idle mode Engine races uncontrollably at full throttle Defective control module on electro...

Страница 18: ...AT EXCHANGER CORE 10 TUBE 11 5411513 1 FAN 12 12 5800387 2 COTTER HAIR PIN 13 6918113 1 HYDRAULIC PUMP 14 5400861 1 BATTERY 14 5401564 1 BATTERY STRAP 15 6901501 1 PUMP BRACKET 15 6901502 1 PUMP BRACK...

Страница 19: ...Figure 6 1 HV1855 Assembly Drawing 16...

Страница 20: ...IAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO THE BUYER OR ANY OTHER PERSON FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL LOSSES OR DAMAGES CONNECTED W...

Страница 21: ...y normal wear and tear by improper adjustment or alteration by alterations not completed by authorized service personnel or by failure of product parts from such alterations 4 Costs of repairing damag...