background image

14 

 

 

 

Engine fails to return to idle after a load is 
removed. 
 

Defective actuator on HV1858 electronic governor is failing to move 
throttle lever—replace actuator as described in the engine manual. 
 
Auto idle switch on HV1858 model has been left in “bypass”—push 
switch down to put engine in auto idle mode. 

Engine races uncontrollably at full throttle. 

Defective control module on HV1858 electronic governor is 
triggering actuator to move throttle to wide open position—replace 
module as described in the engine manual. 

Engine frozen. 

No oil in crankcase—service at engine manufacturer service center or 
replace engine with equivalent. 

Problem with split frame reassembly 

Misalignment of top/bottom halves—align and assemble using grease 
to lube four frame telescoping sleeves, then secure with appropriate 
hardware. 

 
 
 
 

 
 

Содержание HV1858C

Страница 1: ...HV1858C BI DIRECTIONAL HYDRAPAK INSTRUCTIONS REIMANN GEORGER CORPORATION CONSTRUCTION PRODUCTS BUFFALO NY P N 6122018 7 26 12...

Страница 2: ...the HydraPak 5 3 1 1 Checking the Engine 5 3 1 2 Checking the Hydraulic System 5 3 2 Starting and Operating the HydraPak 6 3 3 Stopping the HydraPak 7 4 INSPECTION AND MAINTENANCE 8 4 1 General Mainte...

Страница 3: ...operate this HydraPak or the associated hydraulic tool It is recommended that this checklist be maintained as a permanent record Ensure construction area is secured from all unauthorized personnel Al...

Страница 4: ...amage only accidents 1 3 HYDRAPAK SAFETY LABELS These labels warn you of potential hazards that could cause injury Read them carefully If a label comes off or becomes illegible contact Reimann Georger...

Страница 5: ...hoses or fittings while the HydraPak is running 18 At end of operation secure the HydraPak and the associated hydraulic equipment to prevent unauthorized use Never assume you will find the equipment...

Страница 6: ...iller Breather 100 mesh Electrical Charging System 12 14V 16 AMP regulated to battery Battery Type 12V 15 Plate 400 CCA Fuse Automotive Ignition 5 AMP Blade Type Fan 25 AMP Standard Features Hour mete...

Страница 7: ...ordering spare parts or requesting assistance in service The HydraPak has a product nameplate that shows the model and serial numbers as shown in Figure 2 1 Record the model and serial numbers for fu...

Страница 8: ...f unauthorized personnel Place barricades or secure the area in such a manner that no personnel can be injured 4 Position the HydraPak to minimize the amount of construction debris and dust it receive...

Страница 9: ...nd them at a sharp angle WARNING ENSURE HYDRAULIC HOSES ARE PROPERLY CONNECTED AND IN GOOD CONDITION 3 2 STARTING AND OPERATING THE HYDRAPAK 1 Ensure the flow control lever is in the off middle positi...

Страница 10: ...pment in the same condition that you left it Proceed as follows 1 Let the HydraPak run at idle for about five 5 minutes to cool hydraulic oil and components or for ten 10 minutes under severe operatin...

Страница 11: ...WIRE FROM THE BATTERY TERMINAL WARNING DO NOT ADJUST OR REMOVE HYDRAULIC COMPONENTS LINES OR FITTINGS WHILE THE HYDRAPAK IS RUNNING OR WHENEVER THE HYDRAULIC FLUID IS HOT WARNING LIQUID UNDER HIGH PRE...

Страница 12: ...AND MAINTENANCE 1 The following rules must be observed when doing engine maintenance a Do not check for a spark with the spark plug removed Use an approved tester b Do not crank the engine with the sp...

Страница 13: ...eplace engine oil filter 100 hrs Check clean and replace spark plug 100 hrs Have cylinder head removed and cleaned leaded fuel 100 hrs Have cylinder head removed and cleaned unleaded fuel 200 hrs Repl...

Страница 14: ...d check hydraulic tool requirement c Air in fluid inspect for oil leaks and repair to correct d No work being done open center tools only produce pressure under load No hydraulic oil flow caused by a...

Страница 15: ...psi is too low for the hydraulic tool being used check tool pressure requirement Extension hoses too long a Hoses over 50 feet long add sufficient friction to the hydraulic system to slow down the hy...

Страница 16: ...line Improper type of hydraulic oil as an original equipment manufacturer RGC uses a Grade ISO VG 32 hydraulic oil If you have any questions concerning the type of oil you should use for your HydraPak...

Страница 17: ...ine races uncontrollably at full throttle Defective control module on HV1858 electronic governor is triggering actuator to move throttle to wide open position replace module as described in the engine...

Страница 18: ...8 GPM P 14 5400861 1 BATTERY 5401564 1 BATTERY STRAP 15 6900454 1 PUMP BRKT BF 2A C 1 4 0 6901502 1 PUMP BRACKET COVER 16 5493623 1 POSITIVE BATTERY WIRE 17 5401562 1 TOGGLE SWITCH HV1858 ONLY 18 6001...

Страница 19: ...Figure 6 1 HV1858C Bi Directional Assembly Drawing 16...

Страница 20: ...SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO THE BUYER OR ANY OTHER PERSON FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL LOSSES OR DAMAGES CONNEC...

Страница 21: ...by normal wear and tear by improper adjustment or alteration by alterations not completed by authorized service personnel or by failure of product parts from such alterations 4 Costs of repairing dam...