RG B
C H A P T E R 3
Op e r a t i o n
30
QuadView UHDx/UHDx KVM User Guide
350-12245-01 – updated December, 2019
Figure 3-12
EDID Copy
3.10.2 EDID Upload
The QuadView UHDx accepts external EDID in binary data (
*.bin
) format. To upload EDID to a
Custom EDID register:
1.
Click
Choose
to select an EDID file to upload.
A
File Upload
window appears.
2.
Navigate to the location of the binary EDID file on your computer, and then select that file.
3.
Click
Open
.
4.
Use the
Select Custom Location
pull-down menu to
choose a destination for the uploaded EDID.
5.
Click
Upload
.
1. Internal_4K*2k@60Hz 2 ch
2. Internal_1080P 2 ch
3. Internal_DP_4K*2k@60Hz 2 ch
1. Custom 1
2. Custom 2
3. Custom 3
4. Custom 4
5. Custom 5
6. Custom 6
HDMI
Output
Internal EDID
Custom EDID
Network/
Serial Interface
RAM Temp
1. HDMI 1
2. HDMI 2
3. HDMI 3
4. HDMI 4
5. DisplayPort 5
6. DisplayPort 6
Inputs