RFS INSTALLATION GUIDELINES
HYBRIFLEX
®
CABLE|603400210500|September 2020
Visit
for the most current product specifications
Page 18 of 43
Please follow the included installation instruction carefully. For removal of the jacket we also strongly
recommend the use of a manual jacket stripping tool, examples model JSTRIP-114-2 or JSTRIP-114 for 1-
1/4”
size. Check with you local RFS representative for other cable sizes.
▪
Set the JSTRIP onto a straight part of cable. (a)
▪
Insert a screwdriver into the two support holes and begin turning, maintaining a straight line
–
do not
push in any lateral directions and do not twist or leave the right-angle line. Continue turning by hand
(the screwdriver is needed for the start only) until the jacket is cut completely around, still maintaining
a straight line. (b)
▪
Make a mark onto the cable jacket in 70mm (2.75in) from the beginning of the first cut (that’s 50mm
(2.0in) which is needed for the grounding kit installation and for the part of the tool from the end of
the cutting edge to the end of the tool. (f)
Put the tool onto the cable again, whereby the cutting edge should be in the already jacket stripped area.
Start again, while pushing the tool slowly in direction of the marking. The jacket will be cut in a spiral. Turn
further by pushing the tool very slowly until reaching the marking. If the tool is on the mark, turn further, but
now push a little bit in the reverse direction to finish the cut in straight line.