Radio Frequency Systems
BD1500W Series Air Dryers User’s Guide
Page 54 of 98
100518834 – Rev. B
9.2 Measuring Compressor Amp Draw
With the Compressor running:
9.2.1
Open Front Panel (section 8.5 ).
9.2.2
Locate wire #5 coming
directly from the
Compressor.
9.2.3
Use an Amp Meter to
measure the running amps.
With the Compressor running,
the running amps should
measure:
6.3 amps or below
for the
BD1500W &
BD1500WLP models
3.2 or below
for the BD1502W & BD1502WLP models
If the Compressor measures over running amps indicated above, see section
13.16 for troubleshooting information.
9.2.4
Close Front Panel.
WARNING!
Internal surfaces may be hot
. Use care when coming into contact
with internal components as there is a potential for some these
components to become hot when in operation or standby.