Radio Frequency Systems
BD1500W Series Air Dryers User’s Guide
Page 42 of 98
100518834 – Rev. B
8.8 Connecting to Power Fail Alarm Terminals
8.8.1
Open Panel
8.8.2
Locate the external Power
Fail pins on the Control
Board.
8.8.3
Wire the Power Fail Alarm
wire pair to the Control
Board as required:
PWR FAIL
&
NC
for
CLOSE ON ALARM operation.
NO
&
PWR FAIL
for OPEN ON ALARM operation
8.8.4
Close Panel.
8.9 Connecting via Web Browser
If the Air Dryer IS connected to an IP network:
The Air Dryer must be configured with a valid IP Address, Subnet Mask, and
Gateway Address for the network.
An IP cable is connecting the Air Dryer to the network.
Use a computer that is on the same network as the air Dryer.
Use Internet Explorer (6.0 or newer) or Mozilla Firefox Web Browser.
If the Air Dryer IS NOT connected to an IP network and has not been
configured with IP information:
Use the default IP Address (
192.168.1.100)
of the air dryer to connect.
Use an IP Cable (may require Cross-over cable) plugged directly into a
Laptop/PC and the other end plugged into the UTP Port on the Control Board
of the Air Dryer.
Configure the network card on the Laptop/PC to use the IP Address
192.168.1.101
. This will make the Laptop/PC compatible with the Air Dryer.
Use Internet Explorer (6.0 or newer) or Mozilla Firefox Web Browser.
Содержание BD1500W Series