background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Mounting Hardware 

APM40  

 

RADIO FREQUENCY SYSTEMS 

®

  

Antennas 

Antenna  Interface Configuration                

 

 

 

 

 

                                                                                               Document Reference: 10000000985             Version 2 

 Applications 

 

The APM40 Kits are mounting hardware options to be 
used for Base Station antennas up to 2.6 meters length.  
The same APM40 can be mounting with 2 different 
Antenna interface : Configuration     

A

 and 

B

 

 Features 

 

Features include: 

  Basic direct mount kit

 

  Beam sliding tilt mount for mechanical tilt

 

  Scissor tilt option for fixed at mast (or wall) downtilt

 

  Option for azimuth adjustment independent of mast

 

  All kits fully upgradable

 

  Pipe diameter : 60-120 mm, Wall mount option

 

  Mechanical downtilt,  depending of antennas

 

  Azimuth adjustment up to +/-30 degrees

 

 Mechanical Specifications 

 

Weight of kit (kg) 

2.8 Max (type of mounting F) 
1.8 Min (type  of mounting A) 

Mounting kit material 

Aluminium, Galvanised steel 

Packaging material 

Plastic sleeve 

Dynamometric Tools 
required 

19 and 18mm AF socket 
10mm AF spanner or socket 

 

 

Please contact technical support for more information. 

 

Mount kit installation 

with antenna  

configuration   

 

 Mounting Options 

 

Refer to the following table to identify mount kits supplied.  The packages of the mount kits are marked with the APM 
variation.  Refer to the relevent Figure in the Instruction for assembly information.  The letter designation is 
referenced in the antenna model description. 

Letter 

Type of Mounting 

Mounting kit(s) 

Figure Reference 

Direct pipe (no tilt) 

APM40-1 

3  

Azimuth upgrade 

APM40-1 & APM40-E3 

6  

Beam tilt 

APM40-2 

4  

Beam tilt with azimuth upgrade 

APM40-2 & APM40-E3 

7  

Beam tilt with scissor upgrade 

APM40-2 & APM40-E2 

5  

Beam tilt with scissor and azimuth upgrades 

APM40-2, APM40-E2 & APM40-E3 

8  

Direct to beam upgrade 

APM40-E1 

4  

 

 

 

 

No mount kit 

 Assembly and Installation 

 

Masonry anchor

(not supplied)

For pipe mounting, bolt front and rear pipe brackets to pipe.  

Tighten from front as rear bracket holds nut captive.  Refer 
to Table 2 for top to bottom mount bracket separation.

Figure 1a : Pipe Mount Installation

Figure 1b : Wall Mount Installation

For wall mounting, fix front bracket to wall with appropriate 
masonry anchors.  Pre-drill holes with centres 134mm 

apart, at top to bottom separation shown in Table 2.

 

 

 

Dia

Pitch      

(mm)

Bolt 

Tension  

(kN)

Torque

 (Nm)

M12

1,75

15,90

40,0

 

TIGHTENING TORQUE VALUES 

Unless stated otherwise, the following general 
tightening torque values shall be used for metric 
hexagon bolts and screws. All bolts must be property 
class 4.8 or over. 

MAINTENANCE                                       

Under normal conditions, no maintenance is necessary. 
However, the antenna should be visually inspected at 
regular intervals for damage (e.g. due to lightning strikes, 
and falling ice).Periodic checks should be performed to 
verify correct torque and bracket clearance settings. 
Accessories provided exclusively by RFS. 

REFERENCE DATA 

Table 1

: Item Numbers for the mount Kit Hardware 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Radio Frequency Systems 

Please visit us on the internet at http://www.rfsworld.com 

Specifications subject to change without notice.

  

 
  these data at any time without prior notice.

 

 

 

Specifications subject to change without notice.

  

 
  these data at any time without prior notice.

 

 

Kits

Separation

Direct
Azimuth
Scissor
Azimuth
Beam
Beam+Azimuth

S1=

Refer to antenna mount

bracket separation for distance

S2=

(S1-316) mm

S1

S2

variable

with tilt

 

 

S1 

S2 

 

 

 

 

Figure 9: Adjusting Tilt with Beam Assembly 

To adjust tilt, loosen top pipe clamp bolts, bolts 
through tilt beam, and bolts at antenna bracket 
base (as shown by arrows).Slide arm up or down 
pipe to achieve tilt. Align Beam mark with 
indicator angle. Tighten nuts to lock in position. 
(Refer to tightening torque values) 

 

BOTTOM 

Slide to 
Adjust  
tilt 

Set angle 

TOP 

Figure 10: Adjusting Tilt with Scissor Assembly 

To adjust tilt, loosen bolts through scissor and tilt 
beam. Loosen bolts at base of antenna to allow 
rotation (as shown by arrows). Fold or unfold 
scissor to achieve tilt angle .Align Scissor mark 
with indicator angle. Tighten nuts to lock

 

position. 

(Refer to tightening torque values) 

 

BOTTOM 

 

Set angle 

Fold/ 
Unfold  

TOP 

       DIRECT         SCISSOR 

Item N°

Description

1

Screw Hex M12x110

2

Bolt Hex M12x130

3

Bolt Hex M12x65

4

Nuts Hex M12

5

Washer Flat M12

6

Washer Spring M12

7

Screw Hex M6x16

8

Washer Spring M6

9

Washer Flat M6

10

Washer Flat M12 diameter 31,5

11

Stub Spacer arm

 

 

 

 

 

 

Figure 11: Adjusting azimuth tilt 

To adjust angle, loosen bolts (as show by arrows) 
through azimuth bracket (top and bottom), and rotate to 
desired angle. Tighten nuts to lock position.

 

 

  R F S   T h e   C l e a r   C h o i c e

®

 

Содержание APM40 Series

Страница 1: ...etter Type of Mounting Mounting kit s Figure Reference A Direct pipe no tilt APM40 1 3 B Azimuth upgrade APM40 1 APM40 E3 6 C Beam tilt APM40 2 4 D Beam tilt with azimuth upgrade APM40 2 APM40 E3 7 E Beam tilt with scissor upgrade APM40 2 APM40 E2 5 F Beam tilt with scissor and azimuth upgrades APM40 2 APM40 E2 APM40 E3 8 Direct to beam upgrade APM40 E1 4 Bracket interface for APM40 APM40 E4 2 7 N...

Страница 2: ...surface of pipe bracket Bottom arrangement as shown in Figure 6 Figure 4 Beam Tilt Assembly for downtilt This assembly attaches to top of antenna Bottom mount assembly is the same as direct mount Figure 3 Ensure tilt indicator has BEAM tilt markings visible Note Indicator marked 2 5m to be used with corresponding antenna length or greater Figure 5 Scissor Tilt Extension Insert scissor arm into bea...

Страница 3: ...ill holes with centres 134mm apart at top to bottom separation shown in Table 2 Dia Pitch mm Bolt Tension kN Torque Nm M12 1 75 15 90 40 0 TIGHTENING TORQUE VALUES Unless stated otherwise the following general tightening torque values shall be used for metric hexagon bolts and screws All bolts must be property class 4 8 or over MAINTENANCE Under normal conditions no maintenance is necessary Howeve...

Страница 4: ...g arrangements are identical APM40 1 and APM40 E3 Figure 7 Azimuth Tilt with Beam Tilt Insert azimuth bracket between arms of tilt beam bolting down onto flat surface of pipe bracket Bottom arrangement as shown in Figure 6 APM40 2 and APM40 E3 Figure 8 Scissor Tilt Extension with Azimuth Insert scissor arm into tilt beam as shown in Figure 5 Insert azimuth bracket into scissor arm and bolt down on...

Отзывы: