HN-1010/1510
Common System Problems
The following table offers suggestions for resolving some common system problems
that the operator may experience from the radio system. If problems persist, contact
the factory for further assistance.
Problem System
Checks
Unit is inoperative
1.
Check for proper DC voltage at the power
connector.
2.
Momentarily remove and reapply power.
No Carrier Detect at
remote units or
intermittent
1.
Check for secure interface connections at the
transceiver.
2.
Check antenna, feedline, connectors, and reflective
power.
3.
If remote unit is in synchronization but
performance is poor, it may indicate antenna
problems. Check for properly aligned antenna
headings.
4.
Verify proper programming of the system
parameters.
Interference is
suspected
1.
Verify that the system has a unique network
address. Nearby systems with same address will
cause interference problems.
2.
If Omni-directional antennas are used with the
remote units, consider using a directional type
instead. This will often limit interference to and
from other stations.
3.
Check RSSI value at the remote. A low value
would correspond to a weak signal strength.
©
2000- 2004 Cirronet
™
Inc
54
M-2410-0010 Rev A