Page 69 of 90
CCT24
Returning to the
I/O Tools
tab, the multi-tab
Configuration
window for each radio can be accessed by
clicking on its
Config
button. The data presented on the first six tabs corresponds to configuration register
Banks 0 through 5 as discussed in Section 4.2 above, with the data on the next two tabs corresponding to
configuration register Bank 6, the data on the next tab corresponding to Bank 7, the data on the following
two tabs corresponding to Bank 8, and the data on the last tab corresponding to Bank 9.
Figure 5.6.2.2
The
Transceiver Setup
Tab is shown in Figure 5.6.2.2 and corresponds to Bank 0. The current values of
each Bank 0 parameter are displayed and can be updated by selecting from the drop-down menus or
entering data from the keyboard, and then pressing the
Apply Changes
button. Note that data is
displayed and entered in Big-Endian order
. The Demo automatically reorders multi-byte data to and from
Little-Endian order when building or interpreting messages.
Figure 5.6.2.3
Figure 5.6.2.3 shows the
System
tab contents, corresponding to Bank 1. The current values of each
parameter are displayed and can be updated by selecting from the drop-down menus or entering data