background image

 

 

    

    

PA516 Series User’s Manual 

 

 

     

 

Asia Pacific | EMEA | Americas 

 

 

 

 

 
 
3. Ordering Information 

 
 

Ordering Information 

RFI Part Number 

Description 

PA516A 

AM RF Power Amplifier 
531KHz – 1250KHz 
240VAC 
19in Rack Mount, 2RU    

PA516B 

 AM RF Power Amplifier 
531KHz – 1750KHz 
240VAC 
19in Rack Mount, 2RU 

 
 
 

 

Table 2 

Содержание PA516 Series

Страница 1: ...User s Manual PA516 Series AM RF Power Amplifier Base Line 1 70 Document Number INS41834 2...

Страница 2: ...e a quality management program which is certified to ISO9001 environmental management system certification to ISO14001 and occupational health and safety standard AS4801 giving you complete confidence...

Страница 3: ...rch 2007 1 3 24 th April 2007 1 4 23rd April 2008 1 5 19th January 2009 1 6 16 th May 2009 1 7 25th July 2013 _____________________________________________________________________________ Disclaimer P...

Страница 4: ...11 6 INSTALLATION 12 7 SETUP AND OPERATION 13 DEFAULT 14 DOWNLOAD 14 HELP 15 RESET REVPWR 15 SET BAUD 15 SET GAIN 15 SET LEVEL 16 SET LVLDELAY 16 SET NAME 16 SET SHUTDOWN RETRY 17 SET VSWR 17 SHOW ID...

Страница 5: ...iewed However RF Industries Pty Ltd accepts no liability for any omissions errors or construed information 2007 2014 RF Industries Pty Ltd All rights reserved Reproduction adaptation or translation wi...

Страница 6: ...PA516 Series User s Manual Asia Pacific EMEA Americas 6 PA516 Series AM RF Power Amplifier Front View Rear View...

Страница 7: ...ion and are packaged in a compact 19inch rack mount 2RU enclosure Figure 1 PA516 Block Diagram Various operating parameters are monitored and out of tolerance status alarm outputs are provided for use...

Страница 8: ...50 ohms Power Connector Fused IEC Inlet fused 5A Power Supply 240VAC 10 800VA maximum Alarm Functions Minor Excessive VSWR Cooling fan speed out of tolerance Internal voltage rail out of limits Major...

Страница 9: ...EMEA Americas 9 3 Ordering Information Ordering Information RFI Part Number Description PA516A AM RF Power Amplifier 531KHz 1250KHz 240VAC 19in Rack Mount 2RU PA516B AM RF Power Amplifier 531KHz 1750...

Страница 10: ...hough the packaging has been designed to provide suitable product protection during shipping it is important to report any visible damage to the carrier immediately It is the customers responsibility...

Страница 11: ...te or transfer the Firmware nor the rights thereof This Firmware License Agreement grants or implies no right title or interest in any intellectual property owned or licensed by RFI Support and Firmwa...

Страница 12: ...hat the air flow is not impeded at either the front or rear of the unit Under no circumstances should the unit be allowed to become wet Ensure that the power source is disconnected before removal of a...

Страница 13: ...command the Power LED will be flashing The alarm status will also be active during a firmware update Initial Setup Connect a VT100 compatible terminal via a straight through 9 pin serial cable to the...

Страница 14: ...TRANSFER SEND FILE Binary menu items Select the relevant BIN application file If presented with the option select XMODEM protocol Press OK and or SEND To cancel a download Send one or more CTRL D char...

Страница 15: ...le Type SET BAUD 19200 Response The new serial baud rate will be activated now Press any key to continue Comment After a key is pressed the new data rate will be active so the terminal data rate shoul...

Страница 16: ...utput power level alarms will be generated SET LVLDELAY Purpose Sets the delay period before a level alarm is raised Syntax set lvldelay 1 99 Example Type SET LVLDELAY 15 Response Delay to Level Alarm...

Страница 17: ...al is applied The Minimum value is 0 which disables the feature and the maximum value is 60 Min SET VSWR Purpose Sets the VSWR alarm level Syntax set vswr 1 00 20 00 Example Type SET VSWR 2 5 Response...

Страница 18: ...e PA VSWR Temp Power Minor Alm Major Alm 56 41 3 40 5 NO ON OK OK OK OK OK Level alarm delay 15 Sec VSWR alarm level 2 50 1 SHOW VERSION Purpose This command displays the firmware version Syntax show...

Страница 19: ...ace Space Backspace sequence when the Backspace key is pressed Data Rate The data rate is preset in the factory to 9600 bits per second it can be changed by software command to another rate See the SE...

Страница 20: ...rear panel Control connector provides a local terminal to configure and report all aspects of the operation of the Power Amplifier The three external control signals are connected via a male DB9 conn...

Страница 21: ...ed Firmware upgrades may periodically be made available and may be uploaded for the PA516 via the Command Line Interface CLI if desired Checking that the RF connectors on all coaxial cables are correc...

Страница 22: ...icas 22 10 Background Material and other resources For Product Briefs User Manuals Firmware Upgrade files or additional information on the RFI range of PA516 products please contact your nearest RFI S...

Страница 23: ...PA516 Series User s Manual Asia Pacific EMEA Americas 23 11 User Notes...

Страница 24: ...are correctly torqued as per manufacturers recommendations onto the corresponding Coupler termination connectors is considered good practice All N Male termination connectors on the RF coaxial connect...

Отзывы: