background image

 

RF Input 

The specified maximum input signal level should be observed to avoid damaging the Rx low-noise  

amplifier (LNA). 

Tx Inputs  

Tx inputs from the network base stations use N (female) connectors.  For optimum performance, 50 

Ohm terminations should always be fitted to any unused Tx Input ports. 

Rx Outputs  

Rx outputs to the network base stations use BNC (female) connectors.  For optimum performance, 

50 Ohm terminations should always be fitted to any unused Rx Output ports. 

Cabling and Connections  

Please ensure that all cabling is installed using good quality cable types.  For all RF cabling, double-

screened or solid-screen coaxial cable types are recommended for optimum performance.  For 

connection integrity, the use of coaxial adapters should be avoided.  All coaxial, DC power and alarm 

connectors should be checked for correct termination to their associated cables,  Coaxial cable 

connectors should be firmly tightened when cables are installed.  DC and Alarm cable connectors 

should have their securing screws used to ensure secure connector mating is maintained. 

PIM Management  

The antenna output of the MSC is a multi-carrier RF path.  As such, good quality silver-plated 

double-screened or solid-screen coaxial cable types, and appropriately rated lightning protection 

devices and antennas are recommended for the reduction of Passive InterModulation (PIM).   

Lightning Protection  

A multi-carrier compatible lightning protector should be fitted to the antenna system connected to 

the MSC.  In conjunction with correctly installed Earthing, this lightning protection device will assist 

in protecting the MSC, and the network base station equipment connected to it, from hazardous 

and transient voltages.  

 

OPERATION 

Green Power LED 

The green LED on the rear of the MSC is active when external power is present.  If the green LED is 

not illuminated then either there is no DC power present or the polarity is incorrect. 

Red Fault LED 

The red LED on the rear of the MSC will illuminate under the following circumstances; 

 

The DC input voltage is too low. 

 

The LNA’s internal amplifier currents are outside their normal operating range.  

Operating Precautions 

 

There is no On/Off switch on the unit.  It becomes active as soon as DC power is 

connected or the AC plug pack is switched on at the AC outlet. 

 

Do not operate the unit outside its stated specifications. 

 

Do not open the MSC as there are no user-serviceable parts or adjustments inside.  Faulty 

equipment should only be repaired by qualified technical personnel – or returned to the 

supplier for repair.   

 
 

 

User Manual and Help 

For more detailed information on the MiniSystem 

Combiner (MSC), refer to the MiniSystem Combiner 

User Manual -  or contact your nearest Sales Office.   

www.rfi.com.au

 

 

 

SPECIFICATIONS 

 

Model MSxxxx-0y05-SP 

1313 

1314 

1415 

1516 

1517 

1616 

1617 

Frequency Range (MHz) 

132-142  138-148  148-158  155-165  151-172  160-170  164-174 

Tx Channel Capacity 

≤2

 (2 Channel Models)    

4 (4 Channel Models) 

Tx Input Power 

 50Watts 

Tx Duty Cycle 

 100% 

Tx-Tx Bandwidth 

1.0MHz 

Tx Insertion Loss 

<6dB (2 Channel Models)    <9dB (4 Channel Models) 

Tx-Tx Isolation 

>60dB typ. 

Tx Input Return Loss 

>20dB 

Tx-Antenna Isolation 

>50dB 

Tx-Rx Separation 

4MHz 

min. 

4MHz 

min. 

4MHz 

min. 

4MHz 

min. 

21MHz 

min. 

4MHz 

min. 

4MHz 

min. 

Tx-Rx Isolation 

65dBmin. (70dB typ.) 

Rx Channel Capacity 

≤2

 (2 Channel Models)    

4 (4 Channel Models) 

Rx-Rx Bandwidth 

1.0MHz 

Rx System Gain 

0dB to 30dB (in 1dB steps) 

Rx-Rx Isolation 

>18dB 

Rx LNA Noise Figure 

1.2dB typ. 

Rx Max. RF Input Level 

-10dBm 

Rx Output Return Loss 

>20dB 

Impedance 

50 Ohms 

Alarms 

DC Supply Voltage Low, Rx LNA Fail 

Alarm Outputs 

Dry Relay Form-C  (N.C. / N.O. / CMN) 

Alarm Relay Ratings 

50VDC 1A max. 

RF Connectors 

Tx = N (female)    Rx = BNC (female)    Antenna = N (female) 

DC Connector 

2pin 5mm Phoenix (mating plug supplied) 

Alarm Connector 

3pin 5mm Phoenix (mating plug supplied) 

Enclosure 

7RU 19in Rack Mount (Black) 

DC Power Requirements 

+11VDC to +28VDC 3.5W typ. (polarity protected) 

Grounding 

5mm and 6mm stainless steel studs 

IP Rating 

Indoor Use Only 

Operating Temperature 

-30° to +60°C    -122° to +140°F 

Dimensions (HxWxD) 

133x483x430mm    5.23x19x17in 

Weight 

18.5Kg / 40.7lbs (2 Channel Models)    22.5Kg / 49.5lbs (4 Channel Models) 

 

                     

Notes:

     

xxxx

 in the model number denotes the frequency sub-band.  (i.e. ‘1516’ = 156 to 166MHz) 

                                                  

y

 in the model number denotes the channel capacity.  (i.e. 2 = ‘2’ Channel, ‘4’ = 4 Channel)

 