INDICATORS:
Power:
Indicates power is applied to the EDGE unit.
The LED is off when there is no power. The LED is green under normal power conditions. The LED is orange when the +5V is
OK, and the 4.4V is failed. The LED is red when the +5V and the 4.4V have failed and the System Controller module is powered
by the backup battery.
Ready:
Indicates the EDGE unit has completed its power-on self-test and is ready for use.
The LED is off during start-up and whenever the unit is not ready to receiver user input. The LED is green once the unit is up and
running, and ready to receive suer input. The LED is red and flashing during the factory reset process and will continue to flash
until the unit has restarted.
Alarm:
Indicates the alarm status of the EDGE.
‘Green’ indicates no alarm conditions are present. ‘Orange’ indicates minor alarm
conditions are present.
‘Red’ indicates major alarm conditions are present.
The LED is off during start-up. The LED is green when there are no alarms present (the
‘Door Open’ Minor alarm does not indicate
on this LED). The LED is orange to indicate a Minor Alarm. The LED is red to indicate a Major Alarm.
Donor:
Indicates whether the unit is transmitting the signal received from the Donor source.
The LED is off during start-up and when not ready to repeat. The LED is green when the unit is ready to transmit. The LED is
orange when transmitting (i.e.un-gated) and returns to green when transmission stops. The LED will typically alternate between
green and orange to indicate healthy operation while repeating.
Service:
Indicates whether the unit is transmitting the signal received from the Service area.
The LED is off during start-up and when not ready to repeat. The LED is green when the unit is ready to transmit. The LED is
orange when transmitting (i.e.un-gated) and returns to green when transmission stops. The LED will typically alternate between
green and orange to indicate healthy operation while repeating.
External Indicator:
This LED will be off during power up and self-test. After this time the external Status LED mimics the unit
’s alarm status – ‘green’
when there are no alarms present,
‘orange’ when there is a Minor alarm present, and ‘red’ when there is a Major alarm present.
Содержание DSPbR EDGE Series
Страница 7: ...DSPbR EDGE Series User s Manual Asia Pacific EMEA Americas 7 2 Block Diagram Diagram1...
Страница 33: ...DSPbR EDGE Series User s Manual Asia Pacific EMEA Americas 33 10 15 Configuration Trunking Extender...
Страница 63: ...DSPbR EDGE Series User s Manual Asia Pacific EMEA Americas 63 15 User Notes...
Страница 64: ...DSPbR EDGE Series User s Manual Asia Pacific EMEA Americas 64...