background image

ZULU Telemetry 

Application Example ONE to ONE

 

Zulu 

Transmitter

Input 1 - 10

Zulu 

Receiver

Output 1 - 10

Transmit 

Signal

Acknowledge 

In this application the outputs at the receiver will track the inputs at the transmitter. 

The receiver outputs are acknowledged back to the transmitter. 

If required the Watchdog can be enabled to inform the user if the RF system has a fault. 

Содержание ZULU T

Страница 1: ...ce paired with another Module a remote control system is created Connections for Power antenna and Input Output are the only connections re quired Part No Description ZULU T868 SO Radio Telemetry Modu...

Страница 2: ...as not received acknowledgment or Zulu Rx not received watchdog 16 Vcc In Supply voltage 17 18 TX RX LEDs Out Active LED output when module is transmitting or receiving RF data packets 19 TX RX In Con...

Страница 3: ...r XTAL1 XTAL2 pins 29 30 The Zulu module requires a 30MHz drive crystal to be connected between XTAL1 2 Any standard crystal 10ppm 20pF such as Farnell part no 184 2247 Note tuning ca pacitors are not...

Страница 4: ...uTx will not transmit A nominal 1uF capacitor is recommended across the analogue inputs in order to prevent noise being read and transmit ted Note A maximum of three RF packets are sent per second Dig...

Страница 5: ...T GND 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SWITCH INPUTS 3 7 XTAL SWITCH INPUTS 8 10 Vcc RF Fault Analogue Inputs Vcc NC NC NC Vcc Vcc TX LED RX LED 10K NC Transmitter example application circuit Notes...

Страница 6: ...at the transmitter the output should be fed through an RC network as above Digital outputs CMOS TTL compatible outputs Can be connected directly to CMOS TTL logic or drive Analogue Digital pin 3 This...

Страница 7: ...N Channel Selected is 869 500 Analogue outputs active ZULU T 30 29 28 27 26 25 24 23 22 21 20 19 18 17 ANT GND 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LED OUTPUTS 3 7 LEARN XTAL LED OUTPUTS 8 10 Vcc RF Fau...

Страница 8: ...iver Output 1 10 Transmit Signal Acknowledge In this application the outputs at the receiver will track the inputs at the transmitter The receiver outputs are acknowledged back to the transmitter If r...

Страница 9: ...is affected by many things for example local environmental conditions atmospheric condi tions interference from other radio transmitters For evaluating the local environment please see our RF Meter D...

Страница 10: ...Parameter Min Typical Max Units Supply Voltage 1 8 3 6 V Operating Temperature 40 85 o C Zulu Tx Supply Current When Transmitting When sleeping 85 1 mA uA Zulu Rx Supply Current 18 5 mA AC Characteri...

Страница 11: ...etry System Characteristics Parameter Min Typical Max Units Time from Zulu Tx input activation time to Zulu RX out put Activation 28 ms Time from Zulu Tx input activation time to Zulu RX out put Relax...

Страница 12: ...nal LED Indication of Power Transmit Receiver RF Error The ZULU EVAL Boards provide a ready to go platform which can be used for evaluation or complete projects These boards demonstrate the capabiliti...

Страница 13: ...are read on Power up only Power In 10 x Digital Outputs 2 x Analogue Outputs PWM RS232 Comms not fitted as standard USB Comms not fitted as standard Comms Selector Link All centre to RS232 or All Cent...

Страница 14: ...ter buttons For all other operation please refer to the ZULU Module operation Analogue in PWM Out When using the analogue RF link by turning the potentiometer VR1 or VR2 outputs 1 and 2 at the receive...

Страница 15: ...ZULU Telemetry Zulu evaluation board receiver schematic...

Страница 16: ...ZULU Telemetry Zulu evaluation board transmitter PCB layout...

Страница 17: ...atletud selles dokumendis vastab direktiivi 2014 53 EL n uetele ELi vastavusdeklaratsiooni t ielik tekst on k ttesaadav j rgmisel internetiaadressil www rfsolutions co uk FI RF Solutions Limited vakuu...