MAINSLINK 

Page: 2 

QS-MAINSLINK-9 

PATENT  No 2564512 

Application example: WORCESTER-BOSCH Boiler Installation: 

Operation 
When the Boiler switches the Pump ON, MAINSLINK-TX is switched 
Live, then, MAINSLINK-RX Lout will automatically switch the pump on. 

 Warnings:  

• 

Product is not independently isolated, ISOLATE the mains electricity supply before removing the 
cover and observe any relevant safety precautions. Maintenance to the  product that involves re-
moval of the cover should only be carried out by a competent person or qualified electrician.  

• 

F2 Fuse rating is 4A (T) 250 H (Ceramic). Replace fuse with same type and rating.  

• 

Relay is rated at 10A peak, and 5A constant. 

• 

Product must be connected to a switch fused spur/supply or BS1363 Plug. A single Fuse Spur is 
recommended to supply the Boiler and MAINSLINK jointly so that they are isolated together. 

Jumper Link Setting:

 

There are three Jumper Links which may be used to configure the following:  

WDOG

MODE

MOM/LAT

 Link 

Open 

Fitted 

WDOG 

Watchdog OFF 

Watchdog Active 

MODE 

FM 

LORA Mode 3 

MOM/LAT 

Momentary 

Latching 

WDOG: WATCHDOG: 

This provides improved reliability and security, useful with electrically noisy Loads.  
When the WDOG link is fitted each MAINSLINK automatically sends a background watchdog RF signal and 
expects to receive a corresponding WDOG signal from its partner.  
If the WDOG signal is not received within 90 seconds, the output will drop out and comms LED will flash.  

MODE: 

FM: Fast operation shorter range (Line of sight upto 500m/100m in buildings) 
This mode is recommended for general operation.  
LORA Mode 3: Slower operation Long range (Line of sight upto 5Km/1Km in buildings) 
This mode can be used where additional RF penetration / range is required. 
MOM/LAT 

Momentary or Latching Output

 

MOMENATRY: Used for MAINSLINK TO MAINSLINK. 
LATCHING: Select this when MAINSLINK-RX is controlled by a Remote transmitter - e.g. pocket keyfob.  

MAINSLINK 

Page: 3 

QS-MAINSLINK-9 

PATENT  No 2564512 

Switching Lower Power LED Lights:

 

Mainslink-

RX incorporates a “snubber” protection circuit which is 

recommended with Inductive Loads such as a Motor or pump. 

 

If switching lower power LED lighting the snubber circuit can cause 
the LED lights to faintly glow when switched off.  

To remove the snubber, remove Jumper link J2 on the rear of the PCB  
(as image shows). 

1. Apply a 230Vac supply to the MAINSLINK-RX 
2. Briefly swipe a magnet along Right side as shown  
3. 

The GREEN comms LED will flash 3 times to show “in 
Pairing Mode”.

 

Erasing a MAINSLINK-RX 

1. Apply a 230Vac supply to the MAINSLINK-TX 
2. Briefly swipe a magnet along left side as shown  
3. MAINSLINK-TX will now send a special Pairing message 
4. The MAINSLINK-TX  and MAINSLINK-RX will now Auto pair 

together - allow 15 secs. 

To erase the system hold a magnet beside the top left side 
of the enclosure until the Green COMS LED is ON solid 
(about 5 seconds). 

 

Pairing a MAINSLINK-TX to a MAINSLINK-RX  

NOTE: This system does not require pairing, they are supplied ready to operate! 

MAINSLINK-RX  COMMS LED  

Operation  

2 x Flashes 

3 x Flashes 

 

 

Status 

Unpaired 

In Pairing Mode 