DS-ELITE-L-3          PAGE 7 

 

Technical Specifications 

 

Transmitters: 

ELITE-T8

 

Enclosure Rating:  Not waterproofed 
Battery Type: 

CR2032 (supplied)  

Battery Life:  

3 years @ approx 50 1/2second presses p/day 

Dimensions:  

86 x 54 x 7 mm  

Changing the Battery: 

Carefully squeeze in the battery lock tab on the base of the transmitter, and then pull out 

the battery tray  

 

Transmitters: 

ELITE-XTn

 

Enclosure Rating:  Standard IP68 
Battery Type: 

3 x AAA (supplied)  

Battery Life:  

5 years @ approx. 50 1/2second presses p/day 

Dimensions:  

90 x 54 x 27 mm  

Changing the Batteries: 

Remove the six fixing screws. Remove the 2 battery compartment screws, remove the 

battery compartment and replace batteries inside it, taking care not to damage cables and ensuring correct battery 
polarity 

 

 

Receiver Decoder: 

ELITE-RXL 

Enclosure Rating:   

IP68   

Dimensions:  

 

267 x 148 x 78 mm (not including antenna) 

Storage Temperature:   -10 to +70

Celsius. 

 

Operating Temperature:  -10 to +50

Celsius. 

 

*The relay contacts in this unit are for functional use only and must not be used for isolation purposes

 

 

Approvals Information: 

• 

All RF Solutions products are manufactured in accordance with our ISO:9001 Quality System 

• 

ELITE Systems are manufactured to CE standards 

• 

Further information available on request. 

 

Electrical Characteristics

 

Min

 

Typical

 

Max

 

Units

 

Supply Voltage 

  

  

Frequency:   

 

869.500 

 

MHz 

RF Output Power (ERP) @ 86MHz 

 

mW 

Electrical Characteristics

 

Min

 

Typical

 

Max

 

Units

 

Supply Voltage 

  

4.5 

  

Frequency:   

 

869.500 

 

MHz 

RF Output Power (ERP) @ 869.50MHz 

100 

 

mW 

ELECTRICAL CHARACTERISTICS

 

MIN

 

TYPICAL

 

MAX

 

DIMENSION

 

Supply Voltage for MAINS 

 

 230Vac 

+10% 

Vac 

Relay Rating* (230Vac) RLY1-4 

 

 

A(rms) 

Supply Current :   

Quiescent 

 

 

All relays operating* 

25 
90 

30 

120 

60 

170 

  

mA 

Time delay from Tx on Switch to Rx Relay operation 

  

30 

 

mS 

Time delay from Tx sw relax to Rx Relay release 

  

30 

 

mS 

Supply voltage for LOW VOLTAGE 

12V 

24 

32 

Vac/Vdc 

Содержание ELITE-L Series

Страница 1: ...terproof IP68 enclosure will be a great choice The ELITE remote control system has been designed with the requirements of electricians in mind and therefore it can be used to switch all lighting types...

Страница 2: ...itter 16 switch 8Sw Shift Key ELITE XT8 Transmitter 8 switch Part Number Description Receiver Power Supply Range Metres ELITE S4L System 4 outputs With ELITE T8 230Vac 250 ELITE RXL Receiver 4 output...

Страница 3: ...age Dry Contact Remote control System ELITE Low Voltage Dry Contact Remote control System ELITE Low Voltage Dry Contact Remote control System ELITE Low Voltage Dry Contact Remote control System DS ELI...

Страница 4: ...er box in the wall in your desired location see Page 8 for wall mounting dimensions and information 3 Open the enclosure by removing fixing screws from the enclosure front and then removing the front...

Страница 5: ...showing that out put 1 is selected Pressing the SYNC button again will select output 2 and so on through to output 4 4 Once you have selected the required output that output LED only is flashing pres...

Страница 6: ...set any output to de activate after a different amount of time should you wish to 1 To enter timer select mode Press the TIMER button 2 Select your chosen output by pressing the TIMER button to scroll...

Страница 7: ...correct battery polarity Receiver Decoder ELITE RXL Enclosure Rating IP68 Dimensions 267 x 148 x 78 mm not including antenna Storage Temperature 10 to 70o Celsius Operating Temperature 10 to 50o Cels...

Страница 8: ...ing Notice Meets the following EC Directives DO NOT Discard with normal waste please recycle ROHS Directive 2002 95 EC Specifies certain limits for hazardous substances WEEE Directive 2002 96 EC Waste...

Отзывы: