background image

RF-LAMBDA USA            www.rflambda.com   

Sales: [email protected]       Technical : [email protected]

W

ide B

an

d E

M

C B

en

ch

top

 Pow

er A
mp

lifier 

 18

GH

z ~ 

40

GH

z

REMC18G40GC

Rev 1. 02-02-2021

Important Notice

Amplifier Outline Drawing: 

All Dimensions in mm [inches]

The information contained herein is believed to be reliable. RF-Lambda makes no warranties regarding the information contained herein.

RF-Lambda assumes no responsibility or liability whatsoever for any of the information contained herein. RF-Lambda assumes no responsibility

or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and

with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to

change without notice. Customers should obtain and verify the latest relevant information before placing orders for RF-Lambda products. The

information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or

any other intellectual property rights, whether with regard to such information itself or anything described by such information.

RF-Lambda products are not warranted or authorized for use as critical components in medical, life-saving, or life sustaining applications, or

other applications where a failure would reasonably be expected to cause severe personal injury or death.

506

.9

4 [

19.

95

8]

25.

75

 [1.

01

4]

46.

11

 [1.

81

5]

482.6 [19.000]

465 [18.307]

133

.2

 [5.

24

4]

11 [0.433]

7 [

0.

27

6]

447

 [17

.5

98

]

436.8 [17.197]

PN:REMC18G40GM

Freq:18-40GHz

Содержание REMC18G40GC

Страница 1: ...ical Supply Voltage 110V 220V AC Typical Applications Wireless Infrastructure Military Aerospace Test and Measurement Parameter Min Typ Max Units Frequency Range 18 40 GHz Gain 48 50 dB Gain Flatness...

Страница 2: ...edure Environmental Specifications and Test Standards Parameter Description Operational Temperature 0 50 Ambient Temperature Storage Temperature 40 85 Thermal Shock 0 50 5 Cycles 10 hours Random Vibra...

Страница 3: ...n with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Страница 4: ...EMC Equipment User Manual Front Panel Rear Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Instrument AC power supply switch Fuse Holder Main AC conn...

Страница 5: ...nate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is...

Страница 6: ...election Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on fr...

Страница 7: ...Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the com...

Страница 8: ...with such information is entirely with the user All information contained herein is subject to change without notice Customers should obtain and verify the latest relevant information before placing o...

Отзывы: