background image

Rev

 

2.

 

01

11

2021

RF-LAMBDA USA            www.rflambda.com   

Sales: [email protected]       Technical : [email protected]

REMC08G11GE

400W 8-11GHz 

EMC-Benchtop 

Solid State

Power 

Amplifier

Self

 

Calibration

 

Screen

Instrument

 

Protection

 

Alarms

The

 

front

 

panel

 

LCD

 

screen

 

will

 

display

 

the

 

error

 

code

 

or

 

error

 

message

 

when

 

instrument

 

self

 

protection

 

is

 

triggered.

 

Front

 

panel

 

alarm

 

indicator

 

will

 

light

 

up.

To

 

eliminate

 

the

 

error

 

code,

 

press

 

“RESET”

 

on

 

front

 

panel

 

keypad

 

to

 

reboot

 

the

 

instrument

 

and

 

clear

 

the

 

alarms.

If

 

error

 

code

 

can

 

not

 

be

 

eliminated

 

after

 

reboot,

 

please

 

contact

 

[email protected]

Calibration

 

is

 

may

 

be

 

recommended

“[1]

 

Calibrate”

 

to

 

execute

 

instrument

 

self

 

calibration

 

process.

“[2]

 

Reset”

 

to

 

reboot

 

the

 

instrument.

*Please

 

turn

 

OFF

 

RF

 

input

 

power,

 

and

 

terminate

 

the

 

RF

 

output

 

port

 

while

 

applying

 

calibration

 

function

Switching

 

On

 

Instrument

Please

 

follow

 

the

 

instructions

 

on

 

the

 

front

 

panel

 

LCD

 

screen

 

after

 

switching

 

on

 

the

 

power.

Press

 

“1”

 

on

 

keypad

 

to

 

continue.

Front

 

Panel

 

LCD

 

Screen

 

Display

 

Содержание REMC08G11GE

Страница 1: ...AC Typical Applications Aerospace and military applications Test and Measurement Research and Development Parameter Min Typ Max Units Frequency Range 8 11 GHz Gain 56 dB Gain Variation Over Temperatur...

Страница 2: ...ngs Biasing Up Procedure Environmental Specifications and Test Standards Parameter Description Operational Temperature 40 85 Case Temperature Storage Temperature 50 105 Thermal Shock 40 85 5 Cycles 10...

Страница 3: ...on with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Страница 4: ...USA www rflambda com Sales sales rflambda com Technical support rflambda com REMC08G11GE 400W 8 11GHz EMC Benchtop Solid State Power Amplifier Gain Gain vs Output Power Saturation Power vs Frequency...

Страница 5: ...wer Amplifier Display Gain Adjustment Knob ON OFF switch Instrument AC power supply switch USER CONTROL D SUB Connector low voltage 3 3V TTL control signals See page below for more information Front P...

Страница 6: ...minate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration i...

Страница 7: ...Selection Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on...

Страница 8: ...driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when...

Страница 9: ...fy the latest relevant information before placing orders for RF Lambda products The information contained herein or any use of such information does not grant explicitly or implicitly to any party any...

Отзывы: