background image

Rev

 

2.

 

01

11

2021

RF-LAMBDA USA            www.rflambda.com   

Sales: [email protected]       Technical : [email protected]

REMC08G11GE

400W 8-11GHz 

EMC-Benchtop 

Solid State

Power 

Amplifier

Ensure that the amplifier input and output ports are safely terminated into a proper 50 ohm load before turning on the power.
Never operate the amplifier without a load. A proper 50 ohm load is defined as a load with impedance less than 1.9:1 or return
loss larger than 10dB relative to 50 Ohm within the specified operating band width.

Power Supply Requirements
Power supply must be able to provide adequate current for the amplifier. Power supply should be able to provide 1.5 times the
typical current or 1.2 times the maximum current (whichever is greater).

In most cases, RF

Lambda amplifiers will withstand severe mismatches without damage. However, operation with poor loads

is discouraged. If prolonged operation with poor or unknown loads is expected, an external device such as an isolator or
circulator should be used to protect the amplifier.

Ensure that the power is off when connecting or disconnecting the input or output of the amp.

Prevent overdriving the amplifier. Do not exceed the recommended input power level.

Adequate heat

sinking required for RF amplifier modules. Please inquire.

Amplifiers do not contain Thermal protection, Reverse DC polarity or Over voltage protection with the exception of a few
models. Please inquire.

Proper electrostatic discharge (ESD) precautions are recommended to avoid performance degradation or loss of functionality.

What

 

is

 

not

 

covered

 

with

 

warranty?

Each RF

Lambda amplifier will go through power and temperature stress testing.

Since the die, ICs or MMICs are fragile, these are not covered by warranty. Any damage to these will NOT be free to repair.

Amplifier Use

Part

 

No.

Description

REMC08G11GE

8GHz~11GHz

 

Power

 

Amplifier

Ordering

 

Information

Содержание REMC08G11GE

Страница 1: ...AC Typical Applications Aerospace and military applications Test and Measurement Research and Development Parameter Min Typ Max Units Frequency Range 8 11 GHz Gain 56 dB Gain Variation Over Temperatur...

Страница 2: ...ngs Biasing Up Procedure Environmental Specifications and Test Standards Parameter Description Operational Temperature 40 85 Case Temperature Storage Temperature 50 105 Thermal Shock 40 85 5 Cycles 10...

Страница 3: ...on with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Страница 4: ...USA www rflambda com Sales sales rflambda com Technical support rflambda com REMC08G11GE 400W 8 11GHz EMC Benchtop Solid State Power Amplifier Gain Gain vs Output Power Saturation Power vs Frequency...

Страница 5: ...wer Amplifier Display Gain Adjustment Knob ON OFF switch Instrument AC power supply switch USER CONTROL D SUB Connector low voltage 3 3V TTL control signals See page below for more information Front P...

Страница 6: ...minate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration i...

Страница 7: ...Selection Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on...

Страница 8: ...driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when...

Страница 9: ...fy the latest relevant information before placing orders for RF Lambda products The information contained herein or any use of such information does not grant explicitly or implicitly to any party any...

Отзывы: