3. RF Input Port( F type)
4. RS232(1)
Preinstalled for the use of the CPU, convenient for monitor control.
5. RS232(2)
Preinstalled for the use of the CPU, convenient for monitor control.
6. AC power socket (220VAC 50Hz)
The Voltage range should be 100~250VAC.
5. Installing
Invisible optical beam comes out from the end of the optical
connector, permanent damage would happen to eyes if see it directly.
1. Fiber connection
Power off, carefully remove the protective cap from the end of the FC/APC /
SC/APC connector, insert the clean optical connector into the mating
receptacle and tighten the connector securely.
2. Power
Turn the “power ON/OFF” Lock to ON position. Apply power to this
transmitter, the Power Indicating Lamp lit green when the power is normal.
Otherwise, cut off the power immediately(and so on in the abnormal power
in the future), and contact with supplier.
This machine should be safely ground.
3. LCD display and lamp indication
LCD shows “PLEASE WAIT…”.
After a moment, shows “LASER TEMP 2
×
℃
”(between 23
℃
∼
27
℃
) and
“COOL CUR
×××
mA”.
Press the “Status Indicating” switch again, the LCD will show “OPT POWER
××
mW” and “BIAS CUR
××
mA”.
Press the “Status Indicating” switch again, the LCD will show “LOCAL
ADDRESS
××××××
H”.
Press the “Status Indicating” switch again, the LCD will show “POWER
××
.
×
V
×
.
×
V
×
.
×
V”.
Repeat the above steps for several times, if the specifications are almost the
same, it means the transmitter is on normal working status.
4. The alarm lamp on the front panel is lit red first then turns green after the
LCD shows massage.
All manuals and user guides at all-guides.com