RFX-RMR
Issue 1.0
page 29 of
41
The
▲▼
buttons are used to select the required output format and the Enter
switch used to select and
store the setting.
9.5.6 SDI / ASI Output Configuration
The Receiver provides two digital output BNC connectors that can be configured to provide two SDI or
two ASI outputs, or one of each.
Two identical menus are provided. One for each output connector: SDI / DVB-ASI 1 and SDI / DVB-
ASI 2.
Title Output
SDI Digital
BNCs
ASI Digital
BNCs
The
▲▼
buttons are used to select the required output format and the Enter switch used to select and
store the setting.
9.5.7 ASI
Output
Format
The Receiver ASI outputs can be configured to provide one of three formats.
Title Output
204
204 byte output packet
188
188 byte output packet
Byte
Single BYTE packets
The
▲▼
buttons are used to select the required output format and the Enter switch used to select and
store the setting
9.5.8 Aux.
supply
A swit12 VDC is provided on the Auxiliary D type connector on the receiver back panel (as
mentioned in clause 6.10). This may be used to feed external equipment e.g. an LNA. The +12 VDC
may be switched “on” or “off” through this menu.
9.5.9 Relay 1 and Relay 2
Two auxiliary switching relays are provided on the Auxiliary D type connector on the receiver back
panel (as mentioned in clause 6.10). These may be used to control external equipment. The operation
of the two relays is controlled through this menu.
9.5.10 LCD Timeout
This function Enables or Disables the automatic switching off of the LCD backlight function.