D301362 Issue 0 October 2021
Page 3 of 40
EN - ENGLISH
Technical Data Photon-P
This table replaces the technical data given on Page 8 of the Photon Installation Manual
Model
PHOTON
25-P
35-P
45-P
55-P
65-P
70-P
100-P
120-P
Combustion Air and Flue Type
1
B23 / B53 / C13 / C33 / C53
Heat Input (Hs)
2
High Fire
kW
32.40
38.80
51.60
58.00
70.00
86.00
119.00
144.00
Low Fire
kW
17.82
19.20
26.83
29.16
42.57
47.30
59.50
73.80
Heat Input (Hi)
3
High Fire
kW
29.72
35.60
47.34
53.21
64.22
78.90
109.17
132.11
Low Fire
kW
16.35
17.61
24.61
26.75
39.06
43.39
54.59
67.71
Heat Output
High Fire
kW
27.03
32.25
42.81
49.29
58.47
72.27
99.03
121.73
Low Fire
kW
15.61
16.80
23.47
25.89
37.21
41.58
52.37
65.09
Gas Consumption (Hs) G31
4
High Fire
m
3
/h
1.22
1.46
1.94
2.18
2.63
3.23
4.48
5.42
Low Fire
m
3
/h
0.67
0.72
1.01
1.10
1.60
1.78
2.24
2.78
Gas Consumption (Hs) G31
4
High Fire
l/h
4.52
5.42
7.20
8.10
9.77
12.00
16.61
20.10
Low Fire
l/h
2.49
2.68
3.74
4.07
5.94
6.60
8.31
10.30
Gas Consumption (Hs) G31
4
High Fire
kg/h
2.32
2.77
3.69
4.14
5.00
6.15
8.50
10.29
Low Fire
kg/h
1.27
1.37
1.92
2.08
3.04
3.38
4.25
5.27
Thermal Efficiency High Fire G31 (NCV)
%
90.9
90.6
90.4
92.6
91.1
91.6
90.7
92.1
Gas Connection
5
BSP
½”
¾”
1”
Flue and Combustion Air Connection Collars (Indoor)
100
130
Maximum Flue Length
m
9.0
Airflow
m
3
/h
3035
4120
4562
5877
7125
8681
10350
17552
Motor Speed
rpm
934
1328
1320
925
1335
1384
1332
1206
Temperature Rise at Maximum Airflow
K
27
23
28
25
24
25
29
21
Horizontal Throw
m
26
27
26
32
32
36
36
36
Noise Level
6
dBA
49
51
51
51
56
59
60
62
Minimum Mounting Height
7
m
2.5
Total Electricity Rating
W
256
550
550
690
820
1000
1040
1900
Electrical Connection
230V / 1N / 50Hz
Protection Grade
IP
IP20
Net Weight
kg
58
89
99
121
122
135
168
258
1.
Gas appliance classification for approved venting methods are based on EN 1749:2020
2.
Refers to gross calorific value of fuel
3.
Refers to net calorific value of fuel
4.
Propane gas: G31 Hs 95.65 MJ/m³ @ 15°C and 1013.25 mbar
5.
There is a difference between the gas connection diameter and the diameter of the supply line. Always use the most adequate
diameter of the supply line to minimise the pressure drop through the gas pipes. If necessary, reduce the diameter of the supply line
at the inlet of the unit.
6.
Sound pressure measured in dB(A) at 5m distance from the heater with A=160m
2
and Q=2
7.
Minimum height from floor to bottom surface of the heater for safe use of the heater. Positioning of unit heaters for performance is
application dependant. Operation is affected by other air moving equipment in the room space, obstructions to the airflow,
draughts and/or close proximity to doors or windows etc. Care should be taken to avoid mounting the heaters higher than these
recommendations unless downturn nozzle options are used, as significant stratification may occur resulting in poor floor coverage
and higher energy losses through the roof structure. Isothermal cond/- 20°C ambient air temperature, discharge louvres zero
deflection, v=0.5m/s. The airflow will be influenced by the height of the building, mounting height of the unit, ambient temperature
and adjustment of the louvres.