Step 6

Drill the wall then fix the backbox in position.  Lift the chassis
(using lifting gear if necessary) onto the studs on the back box
brackets.  Refit and tighten the nuts.

Step 7

It is the sole responsibility of the installer to ensure that the
points of attachment to the building are sound.  Consultation
with the consultant/architect or owner of the building is
recommended to ensure that a sound, mechanically stable
installation is achieved.

All attachments must be capable of supporting the weight of the
product detailed in Section 1.

It is recommended that the chassis is removed from the back box to
avoid having to support the weight of the product during 
installation.  To separate the chassis from the back box undo and
remove the nuts shown and lift the chassis away from the back box.

The product can be installed using either M12 drop rods or 
fastened direct to the wall using appropriate sized fixings suitable
for the wall surface and the weight of the product.

Step 1

2  Installation details

Remove all packaging.  Remove decorative cover.  Undo screws
securing the outlet. 

Note  All outer metal surfaces are covered by a protective plastic
film, which must be removed before final fixing and operating of
the  unit.

Adjust the grille by turning the screw inside with an allen key.

Step 2

Step 3

Step 5

Step 4

To wall mount the product, position the back box against the wall
at the desired mounting height and mark through the holes in
the back box brackets to enable the wall to be drilled for the
appropriate fixings.

5

Содержание AirBloc AC Series

Страница 1: ...AC COMMERCIAL RETAIL ELECTRICALLY HEATED AMBIENT LPHW 1000 1500 2000mm High Standard Capacity Installation and operating manual...

Страница 2: ...Technical specification safety details Installation details Servicing Element and motor replacement General user instructions Fault finding Spare parts 5 4 3 2 1 6 7 Index...

Страница 3: ...installed horizontaly directly over the door opening It is recommended that the air curtain is installed on the inside of the building within the open room space against a wall or ceiling Care must be...

Страница 4: ...Figure 1 Wiring Diagram Electric 2 Drawing Number 900092R1...

Страница 5: ...Figure 2 Wiring Diagram Ambient LPHW 3 Drawing Number 900220...

Страница 6: ...62 992 1095 1138 1500mm 1562 1492 1553 1638 2000mm 2062 1992 2053 2138 Dimensions Technical specification Electric 415V 50Hz supply required 4 Technical specification LPHW Ambient 230V 50Hz supply req...

Страница 7: ...installation To separate the chassis from the back box undo and remove the nuts shown and lift the chassis away from the back box The product can be installed using either M12 drop rods or fastened d...

Страница 8: ...underneath Step 8 To install the product using M12 drop rods follow instructions from step 4 If the decorative tube is to be used fit this over the drop rod then pass the drop rod through the back box...

Страница 9: ...the access plate Carefully hinge down the access plate Note Take the weight as access plate swings down Step 5 With a soft brush clean away any dust from the motor and elements Check all connections a...

Страница 10: ...or bearing Step 1 4 Motor Replacement Slacken the grub screw securing rotors to the motor shaft remove rotor Step 2 Remove the bolts securing the motor to the chassis Replace motor as required Refit i...

Страница 11: ...rse of the previous steps and test performance of the product Element replacement Carefully remove connections to element noting wiring configuration Step 1 Remove two bolts securing elements Step 2 L...

Страница 12: ...up position For longer periods turn off the mains supply isolator Figure 4 5 1 General user instructions Electrically Heated 10 Figure 5 To operate the air curtain First ensure that the electrical su...

Страница 13: ...uld be identified using conventional fault finding techniques In the event that electrical components are replaced please ensure that electrical safety checks in accordance with the regulations in for...

Страница 14: ...rmal cut out 900001 900001 900001 Element Assembly 7 Spare parts Rating 9kW 12kW 18kW 24kW HE Part No 100526 100527 100528 Length 1m 1 5m 2 0m SE Part No 100840 100841 100842 Length 1m 1 5m 2m Coil LP...

Страница 15: ...489707 UK sales e mail sales ambirad co uk Website www ambirad co uk For commercial retail air curtain enquires please contact Due to continuous product innovation we reserve the right to change produ...

Отзывы: