Bosch Rexroth AG
Hydraulics
VT-HACD-3-2X RE 30543/12.10
Features
– Use as
closed-loop control electronics
for closed control
loops with PIDT1 controller and optional state feedback
– Substitutional closed-loop control (e.g. position control with
superimposed pressure/force control) possible
– Use as
command value electronics
for generating, linking
and standardizing signals
– Input for digital position measurement systems (2 x SSI or
1 x incremental)
– 6 analog inputs, voltage (±10 V, 0…10 V) and current
(4…20 mA) selectable via software, input resistance
of AI1 > 10 MΩ
– 3 analog outputs, 1x selectable voltage (±10 V, 0…10 V) or
current (0…20 mA, 4…20 mA), 2x voltage (±10 V)
– Numerous possibilities of signal linking and switch-over
– Release input and OK output
– 8 digital inputs
– 7 digital outputs, configurable
– Parameterizable ramp function
– 32 blocks with command values, velocities and controller
parameters
– Adjustment to hydraulic drive by means of area adjustment,
characteristic curve correction, overlap compensation,
residual velocity logic and zero point correction
– +10 V reference voltage output
– Serial interface RS232
– Up to 32 electronics can be interconnected for parameter-
ization and diagnosis via the local bus
Fields of application
– Machine tools
– Plastics processing machines
– Special machines
– Presses
– Transfer systems
Technology functions
– Sequence parameterization
– Positioning
– Pressure control
– Force control
– Tables
Hydraulic axes
– Measurement system:
• Incremental or absolute (SSI, Gray, Binary)
• Analog 0 to ±10 V and 0(4) to 20 mA
– Actuating variable output voltage or current
– Freely configurable controller variants
• Position/pressure/force/velocity controller
• Substitutional closed-loop control (position/pressure)
Programming
– User programming using a PC
Operation
– Comfortable administration of the machine and measuring
data on a PC
Process connection
– Digital inputs and outputs,
– Analog inputs and outputs,
– PROFIBUS DP to communicate with a superior control
– EtherNet/IP
– PROFINET RT
Installation
– Top hat rail 35 mm
CE conformity
– EMC directive 2004/108/EC
Applied harmonized standards:
EN 61000-6-2:2005
EN 61000-6-3:2007
More information
www.boschrexroth.com/hacd