10-4
MKD112
Synchronous Motors MKD
19.05.2004 Version7.0 DOK-MOTOR*-MKD*******-PR07-EN-P
Description
Symbol
Unit
MKD112B-048
Cooling mode –
Natural
Natural
Surface
Motor overtemperature
60K
100K
60K /100K
Electric parameters
Characteristic motor speed
n
K
min
-1
3500
Continous torque at standstill
M
dN
Nm
28,0
33,0
42,0
Continous current at standstill
I
dN
A
35,6
43,5
53,4
Peak current
I
max
A
160,2
Torque constant at 20°C
1
)
K
m
Nm/A
0,88
Voltage constant at 20°C
K
E(eff)
V/1000min
-1
80
Winding resistance at 20°C
R
12
Ω
0,22
Winding inductace
L
12
mH
3,1
Number of pole pairs
p
4
Rated data
2
)
Rated speed
n
N
min
-1
2800
2800
2800
Rated torque
M
N
Nm
7,7
18,1
30,6
Rated current
I
N
A
6,9
16,9
27,5
Rated power
P
N
kW
2,7
6,7
11
Rated voltage
U
N
V
227
236
251
Rated frequency
f
N
Hz
187
187
187
Mechanical parameters
Rotor inertia
J
M
kgm²
192,0 x 10
-4
Theoretical maximum torque
M
max
Nm
102
Minimum strand cross-sectíon
4
)
S
mm
2
4
6
6
Thermal time constant
T
th
min
40
40
20
Maximum speed
n
max
min
-1
4500
Motor mass
3
)
5
)
m
kg
34,0
Perm. storage and transport temp.
T
L
°C
-20 to +80
Permissible ambient temperature
6
)
T
um
°C
0 to 40
Max. setup height
6
)
h
m
1000 above NN
Protection category
7
)
IP65
Insulation class (according to DIN VDE 0530 Part 1)
F
Housing coat
Prime coat black in a/w RAL 9005
1
)
2
)
3
)
4
)
5
)
6
)
7
)
K
m
is to be used for calculations with crest values (I
dN
, I
max
). For calculations with root-mean-square values (rated data), the torque
constant K
m
must be multiplied by a factor of
2
.
Values determined according to EN 60034-1. Current and voltage specified as root-mean-square values.
Use the declared value in bracket for motors holding brake.
Applicable to REXROTH INDRAMAT cables. Rated according to VDE0298-4 (1992) and installation type B2 according to EN 60204-
1 (1993) at an ambient temperature of 40 °C.
Without blower unit.
If the limits specified are exceeded, the performance data must be reduced if necessary. For reduction factors, refer to the chapter
entitled “Environmental Conditions”.
Provided the power and encoder cables are mounted properly
Fig. 10-4: Technical data MKD112B-048
Содержание MKD025A-144
Страница 40: ...5 6 General Notes on Technical Data Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 60: ...7 10 MKD041 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 72: ...8 12 MKD071 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 84: ...9 12 MKD090 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 108: ...11 4 Accessories Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P Notes...
Страница 118: ...12 10 Connection System Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 134: ...13 16 Application Instructions Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 138: ...14 4 Handling Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 154: ...16 6 Startup Operation and Maintenance Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 155: ...Synchronous Motors MKD Appendix 17 1 DOK MOTOR MKD PR07 EN P Version7 0 19 05 2004 17 Appendix...
Страница 172: ...17 18 Appendix Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Страница 183: ......