20
Pict. 21 - TECHNICAL DATA PLATE INDICATING GAS TYPE
POWER ADJUSTMENT
The boiler is already set up to function
optimally with a specific type of gas, which
can be identified by consulting the technical
In any case, before running the device it is
ALWAYS necessary to check the following
points:
Commissioning
- That the device has been correctly located
and installed in a location satisfying all the
manufacturer’s requirements as well as any
applicable legislation and regulations.
- That the boiler is correctly plumbed in.
- That the central heating circuit is filled with
water at a suitable pressure.
- That the central heating circuit and all the
boiler’s hydraulic connections are perfectly
tight.
- That the boiler is connected to the mains
electrical supply according to the electrical
code and any other applicable regulations.
- That the boiler is connected to the combustion
gas evacuation system in accordance with all
data plate present on the rear of the
instrument panel.
applicable legislation and regulations and
that the manufacturer’s specifications and
compatible methods listed on the technical
data plate (Pict. 21) are respected. Check that
appropriate diaphragms are fitted whenever
necessary (page 21). Failing to carry out these
checks may make the boiler’s operation
extremely dangerous to the health of people
and animals.
- That the gas supplied by the mains network
connected to the boiler corresponds to that
indicated on the data plate and for which the
boiler is set up.
Running the boiler on gas which is incompatible
with the specifications on the boiler data plate
can prove extremely dangerous to people
and property as well as causing irreparable
damage to the device itself.
- That the entire gas distribution line both inside
and outside the building, as well as inside
REXNOVA
ISA20KWBTST