7. A temperature switch is provided to control oil sump
temperature. See Figure 2 for proposed wiring. There are
two separate circuits in the temperature switch. The low
circuit is to operate the electric fan. It is recommended the
fan motor be operated by the temperature switch through a
motor
starter relay (consult applicable local and
national
electrical codes). The high circuit is provide
d
to operate
either a high temperature alarm or main motor shutdown.
8. Connect power to the motor using an approved wiring
method. See Figure 1 for connection diagrams.
9. Before starting the fan, double-check to ensure there are
no obstructions
t
h
at
could interfere with proper fan
operation and
airflow
.
Verify proper fan rotation, resulting
in air flow directed at the adjacent face of the gear drive.
10. Remove proper condensation plug. See Figure 3 below.
Do not discard. Plug is to be used during cleaning.
NOTES:
AIR SUPPLY AND TEMPERATURE
— Sufficient air supply over
the motor must be assured in all circumstances. Limits of
operating ambient temperature are 14°F to 113°F (–10°C to
45°C).
RESTRICTION ON USE
— Fan blade material is
Polypropylene which is unsuitable and/or not recommended for
certain chemicals. The following is a partial list of unsuitable
chemicals for guideline purposes.
CLEANING
— When cleaning fan, both condensation holes
(Figure 3, Items 1 and 2) are to be temporarily plugged. If this
is not done, guarantee is void. When cleaning electrical
equipment, always use an approved cleaning agent.
Rexnord Industries, LLC, Geared Products, P.O. Box 492, Zip 53201-0492
168-056
3001 W. Canal St., Zip 53208-4200, Milwaukee, WI USA Telephone: 414-342-3131
February 2009 (PN 2128959)
Fax: 414-937-4359 e-mail: [email protected] web: www.rexnord.com
NEW
Appendix E
•
Falk™ Drive One™ Model C Conveyor Drives
(Page 16 of 16)
Sizes M1220 thru M1250
•
Type D Series
PROPOSED TEMPERATURE SWITCH WIRING
DIAGRAM FOR ELECTRIC FANS
L
1
L
2
CONTROL VOLTAGE
LOW CIRCUIT
PURPLE
RED
BLUE
START FAN
MOTOR
HIGH CIRCUIT
SET AT 140°F
(60°C)
BROWN
YELLOW
ORANGE
ALARM OR MAIN MOTOR
CIRCUIT
SWITCH
FALK PART NO.
932716 - NEMA 4 & 13
MS
SET AT 210°F
(100°C)
CUSTOMER WIRING
AND COMPONENTS
AC RATING - INDUCTIVE LOAD - 50% PF
DC RATING - INDUCTIVE LOAD - L/R = 0.26
AC
VOLTS
AMP
DC
VOLTS
AMP
125
250
480
15
15
15
125
250
15
5
0.05
0.03
6-12
24
MAXIMUM CONTINUOUS CURRENT
Reference only.
MS = MOTOR STARTER
Mounting Positions
For Position
A & B
Remove Plug 1
For Position
C
Remove Plug 2
Note: Never use
copper or brass
fastening materials
FIGURE 3
Chloro-Sulphonic Acid
Nitric Acid
Chloroform
Mixture of HNO3-HCL
Esters
1:2 Dichloroethylene
Mixture of HNO3-H2SO4
Benzene
Trichloroethylene
Sulfuric Acid, fuming
Gasoline
Diethyl Ether
Carbon Tetrachloride
Toluene
Chlorine, Liquid
Chlorobenzene
Xylene
POSITION C
2
POSITION B
POSITION A
1
1
FIGURE 2