7. Resilience 

 

Using the original cover the pre-filter Maxi is passable by walking persons.  
For a resilience of cars or lorries there must be used additional shafts and covers which do not 
have to press onto the filter. 

As an installation example, a concrete frame that can be installed 

over the filter. In this way, the load is kept away from the filter when it is driven over and diverted 
to the surrounding soil

 


 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8. Operation and maintenance  

 

The filter basket must be regularly removed with the aid of the removal rod, emptied and, if 
necessary, cleaned. 
The intervals for cleaning the filter must be adapted to the local conditions (leaves, agriculture in 
the vicinity, etc.). In the first few years, we recommend checking about once a month to get a feel 
for how often and when to clean

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PREMIER TECH WATER AND ENVIRONMENT GMBH  

Subject to technical alterations without notice. All rights reserved. Premier Tech is not liable for printing errors. 

The contents of the technical documentation are part of the warranty conditions. All applicable standards and other 

guidelines, as well as accident prevention regulations, must be observed during planning and installation of the 

product. 

Содержание Prefilter Maxi

Страница 1: ...DORW3106 03 08 2021 Vorfilter Maxi ...

Страница 2: ...en bis maximal 350m Er kann Tanks zur Regenwassernutzung bzw Retentions und Versickerungstanks vorgeschaltet werden 3 Funktionsweise Das zu filternde Regenwasser fließt durch einen Zulauf in den Filterkorb dessen Maschen mit einer Weite von 0 9mm mechanische Verunreinigungen zurückhalten Das gefilterte Regenwasser verlässt den Filter durch einen der unten angeordneten Abläufe Die Wasserausbeute be...

Страница 3: ...ei Rohre übereinander gesetzt werden Das Verlängerungsrohr ist ggf gesondert zu bestellen 6 Einbau Beim Einbau ist die Beschädigung von Gebäuden vorhandenen Trassen sowie der Vegetation zu vermeiden Unter dem Filter wird eine gut verdichtete mindestens 100mm dicke Bettung aus Verfüllmaterial angelegt Dieses Material muss tragfähig gut verdichtbar und frostsicher sein z B Sand Kiesgemisch 0 32 Kein...

Страница 4: ...er Filterkorb muss regelmäßig mit Hilfe des Entnahmestabes entnommen entleert und gegebenenfalls gereinigt werden Die Intervalle zur Reinigung des Filters sind den örtlichen Gegebenheiten Laubanfall Landwirtschaft in der Nähe o ä anzupassen In den ersten Jahren empfehlen wir ca monatlich zu kontrollieren um ein Gefühl dafür zu bekommen wie oft und wann gereinigt werden muss PREMIER TECH WATER AND ...

Страница 5: ...cope of delivery 1 x Container 1 x Filter basket with handle 1 x Cover 1 x Seal DN160 with RWZT2191 1 x Seal DN110 with RWZT2151 2 Application area Prefilter Maxi is used for mechanical cleaning of lightly soiled rainwater by means of filtration during the drainage of surfaces up to a maximum of 350m It is to be installed in front of tanks for rainwater harvesting retention and seep away 3 Operati...

Страница 6: ... is realizable by using 2 extensions The extension tube may have to be ordered separately 6 Installation Avoid damaging buildings pipelines and vegetation Underneath the filter there has to be a well compacted water permeable stable layer of filling material of at least 100mm thickness It must be able to take weight compactable and must be frost proof Suggested is gravel 0 32 Do not use cohesive s...

Страница 7: ... must be regularly removed with the aid of the removal rod emptied and if necessary cleaned The intervals for cleaning the filter must be adapted to the local conditions leaves agriculture in the vicinity etc In the first few years we recommend checking about once a month to get a feel for how often and when to clean PREMIER TECH WATER AND ENVIRONMENT GMBH Subject to technical alterations without ...

Страница 8: ... 8 Vorfilter Maxi DORW3106 03 08 21 Premier Tech Water and Environment GmbH Telefonische Fachberatung 038847 6239 0 Specialist advice by telephone 038847 6239 0 www PT WaterEnvironment de info ptwe de premiertech com ...

Отзывы: