background image

M217 Display unit

 

   Re:control

 

 

27-C

 

 

 

Technical data 

Connections 

 

 

VCC: + 8 to 20 V  

    A: 

Bus-communication 

B: Bus-communication 

    GND: 

Ground 

screening 

 
 
 
Max. cable lengths:  100m  (M217 - 

M51 and/or M219 

 

30 m   (M217 - M218 Wall-mounted remote control) 

 

Power consumption: at the M51:   30 - 50 mA   (off –max. brightness) 
 

at the M219: 50 - 100 mA  (off –max. brightness) 

 

Operating conditions

(Humidity class acc. to  DIN 40040),  

 

"+10°... +40°C" 

 
 
Errors and technical modifications excepted. 

Description: Version 0.93 

 

 

System requirements 

Module/ Interface

     

Software version

 

Multiroom module MKII  

0.90 or higher 

Server module 

 

 

1.01 or higher 

M219

 Additional room amplifier 0.90 or higher 

 

 
 
 

Содержание Re:source M217

Страница 1: ...R45of of Dominating Entertainment Revox of Switzerland Re control M 217 Wall Display Unit...

Страница 2: ...Walldisplay 217 Re control...

Страница 3: ...on off Adressing 217 A B operation Adress settings M217 Menu Control Operating with Softkeys Display contrast Main menu Timer menu Timer programming Sleep function Music Server A Selection by ABC B S...

Страница 4: ...rver The IR receiver that is integrated in the display transfers the control signals to the Multiroom equipment M217 Installation advice The ideal installation height for the M217 Display is 140 10 cm...

Страница 5: ...uired activities and who can recognise and avoid potential dangers The details and instructions contained in this Installation manual must always be taken into account to prevent danger and damage Ins...

Страница 6: ...combination Combi solution 4217 M 4218 M Advice The IR receiver must be activated if the wall display is used on its own without a 4218 M keypad In this case the DIL switch 1 on the back of the wall...

Страница 7: ...off the U72 installation cable and feed it through the mouting fixture 5 3 Connect the cable to the screwed terminal block 4 Connect the terminal block with the print connector on the back of the ope...

Страница 8: ...found in the Revox manuals Your contact point for further questions is your nearest Revox dealer Revox Switzerland AG 8105 Regensdorf www revox ch Technical data Technical data Build in depth 20 mm P...

Страница 9: ...l A connection cable is supplied with the M217 M218 combination solution Combination solution M217 M218 Available designs GIRA Standard 55 GIRA E2 GIRA Event GIRA Esprit Colours All colours JUNG CD 50...

Страница 10: ...inal block 4 Connect the terminal block with the print connector on the back of the operator panel 1 5 Locate the operator panel 1 with its frame 3 onto the mounting fixture 4 so that the clip connect...

Страница 11: ...t for setup and operation can be found in the Revox manuals Your contact point for further questions is your nearest Revox dealer or Revox GmbH tel 49 0 7721 8704 0 www revox de Technical data Technic...

Страница 12: ...d only has a connection to the 217 display There is no direct connection to the Additional room amplifier Connection comes pre assembled with the combination solution The connection is made according...

Страница 13: ...ddress Off 4 M217 Address Off Please note ON is with the switch in the upper position M217 Infrared receiver on off If you are combining the M217 display with the M218 remote control which also has an...

Страница 14: ...y Example If the M219 has address 2 address 2 must also be set at the M217 Display Address DIL switch 3 DIL switch 4 DIL position 1 Off Off 4 3 2 Off On 4 3 3 On Off 4 3 4 On On 4 3 Within in one zone...

Страница 15: ...n each side of the bed In A B operation the second 217 has the same address set through DIL switches 3 4 as the first 217 but with DIL switch 2 activated In this way the first 217 works in A and the s...

Страница 16: ...ne The combination can be different in each zone The address and the correct DIL switch settings for that address are always shown next to the M217 or the M219 8 x M219 0 x M217 7 x M219 1 x M217 6 x...

Страница 17: ...M217 Display unit Re control 6 C 7 x M219 1 x M217 6 x M219 2 x M217...

Страница 18: ...M217 Display unit Re control 7 C 5 x M219 3 x M217 4 x M219 4 x M217...

Страница 19: ...M217 Display unit Re control 8 C 4 x M219 2 2 x M217 4 x M219 2 1 1 x M217...

Страница 20: ...so that the M217 display remains clear to use in spite of the large number of options available A Softkey is a key that can be assigned different functions depending on which menu is currently active...

Страница 21: ...the display field with different sources The display can vary depending on which modules are integrated into the M51 and or which software is installed Please note The M51 enables you to give your ow...

Страница 22: ...y on the M217 The first time it is called the following display appears Timer softkey is not available You are in the Server menu Change to another source Timer programming The concept of the timer pr...

Страница 23: ...with the Select softkey Switching time Weekday Volume Select timer source Select tuner station You can scroll through a loop of the selection options by repeatedly pressing the Select key The two squ...

Страница 24: ...r the switch off which is earlier than that chosen for the switch on e g 20 15 08 30 the switch on occurs at 8 15pm on the selected day and switch off occurs at 8 30am on the following day Only switch...

Страница 25: ...by the following letters M Monday T Tuesday W Wednesday T Thursday F Friday S Saturday S Sunday Selection is made from an endless loop of options that you can step through using the softkeys The follo...

Страница 26: ...er DVD CD and Aux Server Please note When selecting the source you should bear in mind that the source that will be selected is what was assigned to the Tuner DVD CD or Aux Server through the M51 Remo...

Страница 27: ...press of Select will bring you to the point where you can select the station you want to listen to If you have selected DVD CD or Aux Server on the other hand you will return to the Switching times s...

Страница 28: ...a Timer selected the required Timer with the Timer softkeys Using the softkeys the Timer can be activated or deactivated Timer status time display If one or more Timers are activated two bell symbols...

Страница 29: ...sted events then the event that occurs at an earlier timepoint defines the switch on and or switch off timepoints Sleep function Using the Sleep function you can define a length of time after which th...

Страница 30: ...rt In the example shown below that was the artist Mike Oldfield with the album Taurus II Server Menu Select a new music program with the Menu softkey on the 217 The following display appears Make your...

Страница 31: ...album or artist name respectively The resulting list shows all albums or artists whose name starts with the selected letter All other entries are suppressed B Album The Album selection allows you to...

Страница 32: ...t From the display below you can see that it was Joe Cocker as indicated by the small arrow pointer Using the two softkeys you can now scroll through the alphabetical listing of the artists Once you h...

Страница 33: ...ock or Classical for example To do this select the Genre softkey in the main menu shown below and press Select Using the two softkeys you can now scroll through the alphabetical listing of the genres...

Страница 34: ...options Playlists are put together either at a PC with the Music server Editor program interactively with the Visor remote control or simply at the music server itself To activate the Playlist option...

Страница 35: ...within the album Once you have pressed the Track softkey a display window opens that shows all the titles from the current album for example Now using the softkeys you can select the desired title as...

Страница 36: ...tion you can play the music from a selected Playlist for example repeatedly without having to make any manual intervention Pressing the Repeat key again deactivates the function Shuffle Using the Shuf...

Страница 37: ...including display and keys as well as the frame with a damp cloth Apply a few drops of non abrasive washing up liquid to the damp cloth to remove any stubborn marks WARNING Thinners acetone and tolue...

Страница 38: ...remote control Power consumption at the M51 30 50 mA off max brightness at the M219 50 100 mA off max brightness Operating conditions Humidity class acc to DIN 40040 10 40 C Errors and technical modif...

Отзывы: