M219 Additional room amplifier
M Series
12
M219 local inputs
See description:
[1] LOCAL IN 1 2 3
Number of local
inputs
DIL switch
4
DIL switch
5
DIL position
0
Off Off
4 5
1
Off On
4 5
2
On Off
4 5
3
On On
4 5
M219 addressing
If you want to control each
M219
individually, to use the alarm function of
the
M51
T
imer
, for example, it is necessary to assign each
M219
its own
address. The maximum number of
M219s
is limited to 8 per zone.
All
M219s
must have different addresses within one zone as otherwise
there may be communication problems.
The revisal of a correct addressing is made in the Setup menu of the
M51
, category
Multiroom
/
Version
. All attached devices (
M219
and/or
M217
) must be listed in the respective zone.
Address
DIL switch
6
DIL switch
7
DIL
switch
8
DIL position
1
Off Off Off
6 7 8
2
Off Off On
6 7 8
3
Off On Off
6 7 8
4
Off On On
6 7 8
5
On Off Off
6 7 8
6
On Off On
6 7 8
7
On On Off
6 7 8
8
On On On
6 7 8