manualshive.com logo in svg
background image

of  

 

of 

The Philosophy of Excellence

 
 

T

T

h

h

e

e

 

 

M

M

 

 

S

S

e

e

r

r

i

i

e

e

s

s

 

 

 

 

 

 

 

 

M

M

2

2

1

1

9

9

 

 

A

A

d

d

d

d

i

i

t

t

i

i

o

o

n

n

a

a

l

l

 

 

r

r

o

o

o

o

m

m

 

 

a

a

m

m

p

p

l

l

i

i

f

f

i

i

e

e

r

r

 

 

 

 

 

of Switzerland

 

:

 

Dd l

Содержание Re:connect M 219

Страница 1: ...of of The Philosophy of Excellence T Th he e M M S Se er ri ie es s M M2 21 19 9 A Ad dd di it ti io on na al l r ro oo om m a am mp pl li if fi ie er r of Switzerland Dd l...

Страница 2: ...OUT 3 DIL Setup switches 1 IR receiver 2 Pre Out 3 Input IN 4 5 Local inputs 6 7 8 Addressing 4 M219 Link 5 IR Link 6 Input IN 7 Channel Select 8 IN Revox MR Bus 9 OUT Revox MR Bus 10 R L Speakers 11...

Страница 3: ...eration various wall mounted controllers or IR receivers can be connected Installation The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a g...

Страница 4: ...tion and maintenance in this documentation Installation and operation Please check the unit and accessories for any signs of transit damage once you have unpacked it Please read the operating instruct...

Страница 5: ...an result in breakdowns fire or an electric shock Power cable Always pull the plug out of the socket while holding the plug housing and not the cable Warranty Device regulations REVOX offers a warrant...

Страница 6: ...ways be left clear of obstructions The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5cm between the unit and any walls or...

Страница 7: ...r 5 IR receiver or wall mounted remote control connections 6 Switching voltage input 7 Stereo Mono switch 8 Multiroom Bus input 9 Multiroom Bus output 10 Speaker connections L R 11 Fuse 12 Power conne...

Страница 8: ...ts If for example only inputs 1 and 2 are used you can set the switches so that you only have to scroll through Inputs 1 2 Input 3 is skipped 2 PRE OUT Preamp outputs L R Using the M219s preamp output...

Страница 9: ...ess Off Please note The switch is in the ON position when it is down You can enter your own personal DIL switch settings in a table included on the last pages of this manual providing you with a recor...

Страница 10: ...ted whose volume should also be controlled by the M219 This means that the M219 speaker output remains active Fixed Volume In this mode the volume control and the M219 output devices are deactivated i...

Страница 11: ...LOCAL IN 1 is transmitted with a fixed strength In this way volume control is carried out with the TV remote control The volume control setting set by DIL switch 3 only has an effect on the local aud...

Страница 12: ...As long as the master device is not switched on all slave sockets remain switched off Once the master device is switched on all the slave sockets the plug in power supply in the above example are swi...

Страница 13: ...9 its own address The maximum number of M219s is limited to 8 per zone All M219s must have different addresses within one zone as otherwise there may be communication problems The revisal of a correct...

Страница 14: ...mote control If it is not possible or not required that the M219 is controlled directly with a remote control a wall mounted remote controller e g M218 or and external IR eye MR 204 can be connected t...

Страница 15: ...of the left and right speaker connectors 3 Mono If only one speaker is connected to the M219 or if the M219 is controlling two speakers each in a different room you should select the Mono operating mo...

Страница 16: ...ion for a further M219 which is connected with a REVOX Multiroom Bus cable A maximum of 8 M219s can be connected in this way Connection is made using a screened and uncrossed RJ45 cable 7 CHANNEL SELE...

Страница 17: ...n connecting A wrong polarity will not cause any damage to the speaker or to the M219 but it can result in imprecise and diffused reproduction that is weak in the base ranges 11 FUSE Fuse Always power...

Страница 18: ...R AUX2 Zone 1 Zone 2 Zone 3 Zone 4 M219 Room Amplifier Further M219 Further IR Module M217 Wall Display M218 Keypad M218 Wall Display MR204 IR Receiver 115V 230V AC Power Loudspeaker z B ReVox IWS65 1...

Страница 19: ...6 7 8 Off Off Off Off Off Off Off Off On On On On On On On On Off Off Off Off Off Off Off Off On On On On On On On On Off Off Off Off Off Off Off Off On On On On On On On On Off Off Off Off Off Off O...

Страница 20: ...al M219 data Power voltage 230 V 115 V Power fuse rating 0 5 A time lag 1 A time lag Power consumption Max 115 Watt Operation 7 Watt Standby 2 Watt at room volume without additional devices Operating...

Страница 21: ...ou the help you need send the M219 carriage free and without any accessories to your national Sales Office Please supply a complete description of the problem and a full return postal address Delivere...

Отзывы: