22
EN
4.3 EVACUATION OF BURNT GASES
This equipment doesn’t need to be connected to a fl ue, but we do recommend installing it under an extractor
hood. The air required for combustion is 2m³/h for each kW of installed power.
4.4 CHECKING THE PRESSURE
The distribution network pressure must meet the following specifi cations:
LPG
ALLOWED from 20/25 to 35/45 mbar
NOT ALLOWED below 20/25 above 35/40 mbar
METHANE - H
ALLOWED from 17 to 25 mbar
NOT ALLOWED below 17 i above 25 mbar
If the gas distribution network pressure on the
installation site doesn’t meet the above values,
inform the gas board and do not turn the unit on
until the cause and a solution have been found. The
distribution network pressure can be taken with a
U manometer (min. defi nition 0.1 mbar), connected
to the pressure outlet behind control panel fi g. 5.
1. Remove the control panel.
2. Remove the screw and sealing washer from the
pressure outlet and connect the manometer.
3. Turn the unit on following the enclosed instruc-
tions and check that the pressure is within the
permitted pressure range.
4. Disconnect the manometer and replace the
screw and the sealing washer in the pressure
outlet.
5. Replace the control panel.
4.5 ELECTRICAL CONNECTION
Before proceeding with the electrical connection,
check the specifications on the data plate. The
appliance is supplied with a power cable.
The installer must make the connection after hav-
ing installed a main switch, which, as well as being
easy to reach, must disconnect all of the contacts
supplying electrical energy to the appliance with
a minimum distance of at least 3 mm between the
poles. The power cable must meet the minimum
standards of H07 RN-F and have a minimum sec-
tion of 5x1.5 mm
2
; it must not be installed near heat
sources and the temperature of the place in which
the appliance is installed must not rise above 50°C.
The appliance must be connected to a good earth.
For this purpose you will fi nd the earth terminal on
the terminal board, identifi ed with the “
” symbol
and to which the earth wire must be connected.
Slide the cable near to the terminal board, hold
the cable in place until you can block it with cable
clamp
. The appliance must also be connected
to an equipotential earth. This connection can be
made using the equipotential terminal marked with
the symbol
, placed under the appliance near the
right rear foot. The equipotential wire must have
a section of 10 mm
2
.