7
EN
OPERATION INSTRUCTIONS
1. Turn on the power supply and select a suitable
vacuum packing bag for the product.
2. Set the processing parameter and select the
sealing temperature. For the details, please refer
to Pages 6-8.
3. Place the vacuum bag at the chamber with the
opening end on top of the sealing bar. Clamp it with
the hook provided.
4. Close the acrylic cover and the machine will
complete the processing procedure automatically.
5. During processing, the vacuum chamber will
form a vacuum self-lock state, the whole heating
and sealing procedure are completed in a vacuum
environment, and the LED display on panel shows
the flow process.
6. When the vacuum indicator on panel lights, the
equipment is under vacuum state, the LED display
shows the timing of vacuum time, and it will enter
into the next work state automatically after the tim-
ing is finished.
7. When the nitrogen filling indicator on panel
lights, the equipment is under filling state, the LED
display shows the reverse timing of filling time, and
it will enter into the next work state automatically
after the reverse timing is finished.
8. When heating indicator lights, the equipment en-
ters into heating work state, and the panel shows
the reverse timing of heating. It will enter into cool-
ing state automatically after the timing is finished.
9. According to time setting, the machine doesn’t
act when cooling, the panel shows “□□” till the re-
verse timing is finished, air is returned, the cover
opens automatically, and the whole processing is
finished. Then prepare the next cycle.
10. Press the E-Stop Button for a sudden condition
under processing state, the machine will go to re-
turn-air action automatically, the cover opens auto-
matically after return-air action, so the processing
ends.
Note:
1. Silicone rubber strip come with one side nerving
and the other for letter and number inserting. It
will have embossed effect on sealing surface.
2. Please do not run the machine without any vacu-
um bag attach. Otherwise, the heating element will
have higher wear and tear.
3. Cut off the power supply and pull out external
plug when no use.
4. The vacuum gauge/meter reading maybe differ-
ent due to different area. At high altitudes, the data
in vacuum meter goes down.
5. Please adopt suitable cooling measure when
processing is done in a high temperature occasion.
6. Please use the vacuum bag whose material does
not bring any poisonous gas in the sealing.
7. The machine should be placed horizontally in the
transportation, the inversion is not allowed. The
transportation must be proceeded strictly accord-
ing to the instructing marks on the shipping case.
8. The machine should be stored in dry, ventilated,
normal temperature place.
9. Mind your head when the lid open, avoid the lid
striking your head.
10. Please ask the professional to solve the prob-
lem, do not do some repair works by yourself.
11. The spare parts should match our machine in