- 13 -
Config - Low Pass Filter:
Each Executive HD Audio Mode is set by default to use a predetermined Low Pass Filter (LPF) to
optimize the microphone performance. This LPF can be deactivated in each mode to allow the
maximum available audio bandwidth to pass. In ‗High Definition‘ mode the LPF is set to 15KHz and in
‗Max Density‘ mode the LPF is set to 8KHz.
Config
– Mic Pop-Ups:*
The user can choose to have Pop-Up notifications inform them of when a microphone is out of range.
Config
– Mics Unmuted at Startup:*
By default the mics go into a muted state when they are removed from the charger. This is done to
prevent handling noise as the microphone is p
laced into position. By selecting ‗Mics Unmuted at
Startup‘, the mics will go into a unmuted state when removed from the charger.
Config - Table Top Master Mute:
The Executive HD System provides two options for microphone mute performance. The default
option allows each microphone to have its own individual mute capabilities as well as a Master Mute
function that will lock all mics into a muted state until the function is disabled. The Master Mute can
only be triggered by a control system via RS-232 or Ethernet.
The second option allows all tabletop microphones to act as a Master Mute, leaving only the
Wearable microphones and XLR adapters with individual mute capabilities. Muting any table top style
microphone will cause all microphones in the system to mute until another tabletop microphone mute
button is pressed. Un-muting a tabletop microphone will cause all tabletop microphones to un-mute
and will return all Wearable microphones and XLR adapters to their previous state of individual mute
capability.
The ‗Tabletop Master Mute‘ mode can be activated by selecting the option in the ‗config‘
tab of the device window.
Note:
When a Master mute is enabled either through the control system or by using Tabletop Master
Mute mode, all Base Stations connected with a bus cable will be affected. You can eliminate the
Master Mute communication between Base Stations by not terminating pin 2 on the bus connector.
Config - Transmit Power:
The Transmit Power of the Base Station can be adjusted to help reduce the operational radius of a
Executive HD System in order to prevent interference from other Revolabs products, or from other
devices operating in the same frequency. The options for transmit power are ‗0-7‘ with ‗0‘
representing the lowest power and ‗7‘ representing the highest power. This configuration setting can
also be controlled using the Base Station front panel display. The default Transmit Power is 4.
Config - Box Address:
Each Executive HD Base Station must be assigned a unique Box Address when Master Mute or
Tabletop Master Mute is being used, and multiple Base Stations are connected with a BUS cable.
The options for Box Address are ‗0-7‘ with ‗0‘ being the default.
Note:
The Master Mute function will not propagate to the entire HD System if each connected Base
Station does not have its own Box Address.