background image

790 Rowntree Dairy Road, Woodbridge ON, Canada L4L 5V3   
Tel: 905-851-6701   Fax: 905-851-8376   [email protected]

w w w . r e v e r s o m a t i c . c o m  

CAUTION

1. For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapor.

2. To avoid damage to motor and impeller, keep construction material such as dry wall spray, construction dust, construction
    debris, etc. off from the power unit and ducts leading to the unit.

INSTALLATION INSTRUCTIONS

GENERAL PREPARATION

1. To install this unit, you may require following tools and materials:
    - Drill 
    - 1 1/4” wood bit for drilling electrical wiring access hole
    - Philips head screwdriver
    - Saber saw or keyhole saw for cutting the wall or cabinet openings
    - Electrical tape
    - Pencil, ruler, measuring tape and level for marking range hood location
    
2. Unpack the unit from the box and lay the unit upside down on a table. Use cardboard or paper to prevent scratching the 
    unit or table.

3. Remove the aluminum-mesh grease filter and install a fluorescent 4 pin 18 / 26 watt light bulb ( such as Panasonic
    FDS18E35/4 or FDS26E35/4 or equivalent - BULB IS NOT SUPPLIED). Reinstall the filter.

.. 2 ..

NOTE:

 To get maximum exhaust, turn ON both fans.

VERTICAL DISCHARGE ONLY

- 1/8” drill bit for drilling pilot holes
- Pliers / Tin snips
- Duct tape
- Electrical connector

PREPARING THE CABINET OR WALL FOR INSTALLATION

1. If the hood will be installed under cabinets that have a recessed bottom, then it will be necessary to attach wood mounting
    strips (Not Included) to the bottom of the cabinet in the location where the unit will mount. The thickness of the strips 
    should be the same as the recess of the cabinet and they should be approximately 2” wide. Install the wood strips using 
    appropriate length of wood screws 

 

(Not Included). Make sure the wood strips line up with the 4 keyholes of the hood. 

INSULATION - 

Minimum 5 Feet

(1” Thick)

BAFFLE

GRILLE

CAULKING

WALLBOX

NOTE:

3 SIDES ONLY, NOT ON BOTTOM 
(IF CAULKING ALL 4 SIDES, 
 MUST HAVE DRAINING HOLES.)

10"

6"

5"

 14.75"

15.625"

3.25"

Fan Speed 
Control

ON / OFF

Switch

Light 

Fan Speed 
Control

Air 

Exhaust

Fresh Air In

3” dia. collar

Fresh Air 

Intake Opening

Baffles

(Must be installed 

in exhaust only) 

Damper

Exhaust 

openings

Electrical 
Knockout

6.75"

7.75"

12"

1.5"

30"

or

 36"

Exhaust

6” dia. 
collar

Fresh 

Air In

3” dia. 
collar

WALLBOX

GRILLE

Insulation

Duct

Pipe

NOTE:

 

Fresh air intake duct 
must be totally insulated

Отзывы: