Preparing for installation: 

 

1. 

This system includes a standard sink top 
faucet without an air–gap. In localities where 
plumbing codes require installation of an air–
gap, contact your local distributor to obtain a 
code approved drain line adapter. 

 
2. 

The reverse osmosis system may be mounted 
to the side of the sink cabinet or set on the 
floor of the sink cabinet. It must be positioned 
to allow access for service and filter changes.  
The assembly should be relatively near the 
faucet to maximize flow rate. 

See Diagram A

 

for a positioning example. 

 
3. 

The storage tank should be located where it 
can be removed if necessary. The storage 
tank may be placed in either the vertical or 
horizontal position without affecting the system 
performance. If there is insufficient space 
under the sink for placement, the tank may be 
located in an adjacent cupboard up to 50 ft. 
away. 

See Diagram A

 for a positioning 

example. 

 
4. 

The faucet should be positioned to allow a free 
flow pattern into the sink. It must be positioned 
to allow ready access to the mounting 
hardware under the sink. 

See Diagram A

 for a 

positioning example. 

 

 

 
 
 
 
 

 

 
 
 
 
 
 

 
 
 

 

Diagram A 

 
 

 
 
 
 
 

 
CAUTION!!

  Extreme care must be 

taken in drilling the hole for the sink–top 
faucet. The surface material of most 
sinks is extremely hard and brittle and 
can be easily chipped or cracked. If you 
are uncomfortable performing the 
following procedure, it is recommended 
that your local distributor be consulted 
for techniques and other assistance.  
The system’s manufacturer accepts no 
responsibility for sink top damage 
resulting from system installation. 

 

CAUTION!!

  

Before grinding or drilling, 

put on appropriate eye protection (i.e., 
goggles) to protect yourself from 
porcelain or metal chips.   

 

CAUTION!!

  

Before grinding or drilling, 

ensure that the drill you are using is UL

 

Laboratories approved and properly 
grounded to prevent electrical shock.  

DO NOT USE DRILL WHILE USING 
OR STANDING IN WATER!! 

 
1. 

BEFORE DRILLING:

 Check under the 

sink in the area that you plan to install 
the faucet and make sure that there is a 
flat surface to secure the mounting 
hardware. A flat space of approximately 
two inches in diameter is needed. 

 

RECOMMENDATION:

 Before drilling or 

grinding mask off the immediate area, 
surround the grinding/drilling location, 
preferably with duct tape or if duct tape 
is unavailable masking tape may be 
used. This procedure should help 
prevent scratching of the sink surface. 

 

2. 

Remove everything from inside the sink 
and surrounding area. Place paper 
towels in the sink to catch the shavings 
from the grinding and drilling. 

 

CAUTION!! 

Porcelain or enamel must 

be completely removed in the drilling 

Preparing for Installation 

Faucet Installation 

Содержание RF Series

Страница 1: ...Membrane System User Manual RF Series 4 Stage 5 Stage 5 Stage with Booster Pump 5 STAGE RESIDENTIAL REVERSE OSMOSIS SYSTEM PICTURED ...

Страница 2: ...RF Series User Manual MKTF 167 C 2 05 17 This page intentionally left blank ...

Страница 3: ...AMETERS 5 MEMBRANE AND FLOW RESTRICTOR ASSEMBLY PROCESS 6 PREPARING FOR INSTALLATION 9 FAUCET INSTALLATION 9 INSTALLATION AND FEEDWATER ADAPTER 11 INSTALLATION OF DRAIN SADLE 13 POSITIONING THE TANK 13 REVERSE OSMOSIS UNIT PLACEMENT AND MOUNTING 13 TUBING CONNECTIONS 14 SYSTEM START UP 14 FLUSHING THE REVERSE OSMOSIS SYSTEM 15 TROUBLESHOOTING 16 SYSTEM DRAWINGS 18 SYSTEM WARRANTY 21 ...

Страница 4: ...or for assistance ESTIMATED REPLACEMENT AND FILTER CHANGE Sediment Prefilters 6 months 1 year Carbon Prefilters 6 months 1 year Carbon Postfilter 6 months 1 year Reverse Osmosis Membrane 1 2 years NOTE The life of the filters and membrane depend on the quality of water supplied to the reverse osmosis system PRE INSTALLATION INSPECTION After opening the shipping container locate the following items...

Страница 5: ... At higher pressure severe damage to the system may result A pressure regulator must be installed on the feedwater source which reduces the water pressure coming into the system WARNING Warranty voided and manufacturer assumes no responsibility for damage to system or property if pressure exceeds 80 PSI 4 Turbidity 1 NTU 5 pH 4 to 11 6 Recommended hardness not to exceed 7 grains per gallon or 120 ...

Страница 6: ...ESTRICTOR ASSEMBLY PROCESS 1 Identify membrane element and flow restrictor color and type depends on membrane being used included in box 2 Identify membrane vessel feed cap 3 Remove feed cap as shown turn counter clockwise 4 Insert membrane in direction as shown ...

Страница 7: ... Series User Manual MKTF 167 C 7 05 17 5 Push membrane in as shown 6 Place feed cap back on as shown turn clockwise until hand tight 7 Connect tube to cap as shown 8 Identify black concentrate drain tube ...

Страница 8: ...ser Manual MKTF 167 C 8 05 17 9 Disconnect black tube by following instructions below 10 Insert flow restrictor in tube 11 Push in flow restrictor until flush with tube end as shown 12 Reinsert black tube as shown ...

Страница 9: ...ce material of most sinks is extremely hard and brittle and can be easily chipped or cracked If you are uncomfortable performing the following procedure it is recommended that your local distributor be consulted for techniques and other assistance The system s manufacturer accepts no responsibility for sink top damage resulting from system installation CAUTION Before grinding or drilling put on ap...

Страница 10: ...TO CUT YOURSELF ON SHARP EDGES Rinse sink then scrub with cleaner to prevent any rusting from shavings and to prepare for faucet installation Plug hole again while rinsing off cleaner Hole must be plugged in order to avoid water dripping below into sink cabinet which may cause damage 9 Remove faucet from package For steps 11 14 refer to Diagram B 10 Slip the small thin rubber gasket over the fauce...

Страница 11: ...ser going up to the faucet Refer to Diagram E for help with this type of valve Secure an adjustable wrench to the fitting on the cold water side of the sink faucet NOT THE REVERSE OSMOSIS FAUCET Secure another adjustable wrench to the smooth corrugated riser line nut Gently undo the riser line from the sink faucet Do not be alarmed There will be water left in the line this is normal However if the...

Страница 12: ... simply screw the T handle valve clockwise until it stops NOTE If hole in copper tube cold water line is not adequately pierced this may prevent sufficient cold water supply to the system and reduce the performance of reverse osmosis processing In this event open and close the self piercing valve several times Feedwater Diagrams Insert black washer into bottom of the feed water connector Use new c...

Страница 13: ...k 2 Hand tighten the plastic shut off ball valve to tank stem CAUTION Hand tighten the valve only DO NOT OVERTIGHTEN If valve is over tightened it will crack and will leak IMPORTANT The tank pressure must be between 8 10 PSI when measured empty This must be measured with a good dial or digital pressure gauge A pop up tire gauge will not give you an accurate reading If you do not have access to a g...

Страница 14: ...tep 3 or 4 in Section 3 simply slip a white 1 4 nylon nut over the red line and insert the 1 4 nylon insert into the end of the tubing Then insert the tubing into the nylon fitting on the feedwater adapter Tighten the nylon nut securely DO NOT OVERTIGHTEN 2 If you have the connection for the icemaker tee as in Step 2 of Section 3 simply slide the 1 4 brass nut over the red tubing Slip the nylon fe...

Страница 15: ...ly four to five hours 2 After the tank has filled open the faucet and drain all the water from the tank until it is empty CAUTION DO NOT USE FIRST TANK OF WATER FROM YOUR SYSTEM The membrane contains a food grade preservative to protect it while in storage This preservative is not harmful however it does not have a pleasant taste Therefore do not use the first tank of water which flushes the entir...

Страница 16: ...logged Clear or replace air gap faucet Check valve on the reverse osmosis membrane housing is stuck Replace check valve The automatic shut off valve is malfunctioning Replace automatic shut off valve Low Water Pressure From Dispensing Faucet Possible Cause Solution Air pressure in holding tank is incorrect This is the 1 reason for low flow from reverse osmosis faucet Open faucet and empty water fr...

Страница 17: ... off valve New carbon postfilter has not been rinsed completely Drain holding tank twice to rinse new carbon postfilter The incoming feedwater TDS has increased An increase in feedwater TDS will also give an increase in product water TDS Tastes and Odors in Product Water Possible Cause Solution Carbon post filter is exhausted Replace filter There is foreign matter in holding tank Clean flush and s...

Страница 18: ...RF Series User Manual MKTF 167 C 18 05 17 SYSTEM DRAWINGS ...

Страница 19: ...RF Series User Manual MKTF 167 C 19 05 17 ...

Страница 20: ...RF Series User Manual MKTF 167 C 20 05 17 ...

Страница 21: ...ithin three 3 months of shipment from the Manufacturer s manufacturing facility In no event shall the Warranty Commencement Date exceed three 3 months from the shipment from Manufacturer s facility The Customer shall provide proof of purchase in order to exercise rights granted under this Warranty If requested by the Manufacturer the Customer must also provide proof of the installation date Proof ...

Страница 22: ...on and manuals for such product Any expressed Warranty or similar representation of performance set forth in the operation documentation for media or resin incorporated into a product by the Manufacturer shall be void and unenforceable unless the feed water requirements set forth in the operating documentation for such product are unequivocally and strictly adhered to Limitations and Exclusions TH...