background image

Duct fan 

REGO Series 

User Manual 

 

Introduction 

Thank you for choosing our product. Reading of this manual 
is  required  for  proper  use  of  the  device  and  absolute 
observance  to  its  guidelines  is  fundamental  condition 
of security.  
All  users  of  the  device  should  have  free  access 
to the manual  and  in  case  of  resale,  the  instruction  must 
be attached to the product. 

Package contents  

- duct  fan  REGO 

- user manual 

Transport and storage 

The  fan  should  be  transported  and  stored  in  the  original 
packaging  in  a  dry  place  protected  from  contamination, 
until it is installed. Moreover, the fan should be protected 
from the shocks. 

 

Application 

Axial  fans  from  the  REGO  series  are  designed  for  wall 
mounting.  They  are  used  for  ventilation  of  small  spaces 
such as a bathroom or kitchen.  
The device in white color version. 

.

 Dimensions (in mm) 

 

MODEL 

ØA

 

ØB

 

ØC

 

D

 

REGO 100 

98 

104 

100 

88 

REGO 120 

123 

128 

120 

88 

REGO 150 

148 

154 

150 

108 

Technical data 

MODEL 

REGO 100 

REGO 120 

REGO 150 

Maximum aiflow [m

3

/h] 

130 

240 

320 

Maximum compression  [Pa] 

36 

45 

60 

Voltage [V] / Frequency  [Hz] 

230/50 - 60 

230/50 - 60 

230/50 - 60 

Rated current  [A] 

0,072 

0,11 

0,138 

Engine speed [rpm] 

2400 

2200 

2000 

Engine power  [W] 

12 

16 

18 

IP protection degree  [-] 

X2 

X2 

X2 

Noise [dB(A)] 

34 

34 

35 

Installation instructions 

In  order  to  accomplish  the  installation  of  the  device 
successfully  and  enable  the  safe  usage  of  the  fan 
in the future, it is essential to follow the instructions in this 
manual. 
Before installing and connecting the fan, check that it has 
not been damaged during transport or storage (breakage, 
distortion). 

Check  whether  the  technical  data  on  the  nameplate 
corresponds to the electrical installation parameters. 

The device should be mounted on a flat surface. 

If  irregularities  are  not  found,  you  can  proceed 
with the installation as follows: 

- connect the power supply according to the wiring diagram 

- assemble ventilation ducts, tighten them with clamps 

- the ventilation ducts should be carried out in accordance 
with  the  duct  manufacturer's  instructions  and  applicable 
local regulations 

- it is not allowed to make ducts in the way shown below: 

 

-  when  starting  the  extraction  fan,  check  the  following 
problems: 

a. the impeller is not working properly 

b. strong vibrations or strange noise 

- if any of the above flaws is not found, turn off the fan and 
mount the junction box 

The  electrical  connection  must  be  in  accordance 
with the wiring diagram in the terminal box. 

Warnings and precautions 

During  the  operation  of  the  device,  the  following 
precautions must be observed: 

-  before  performing  any  work,  the  device  must 
be disconnected from the power supply 

- the fan is intended only for ventilation of rooms with small 
and medium cubature 

- installation height of the exhaust fan min. 2.3 m 

-  the  minimum  distance  between  the  fan  and  the  ceiling 
is 5 cm 

-  if  you  do  not  use  it  for  a  long  time,  it  is  recommended 
to disconnect the device from the power supply 

- a constant supply of fresh air to the room must be ensured 