background image

2.5 

DEVICE TECHNICAL DATA 

* for parameters 90/70

°

C and 0

°

C inlet

** max. 120/90

°

C, 0

°

C inlet, III stage // min. 40/30

°

C, 20

°

C inlet, I stage

*** measurement at the distance 5 m

TECHNICAL DATA 
Product code

FARMER MC-3S

WHFARMERMC-3S-1788

III STAGE

II STAGE

I STAGE

Nominal heating 
capacity [kW] *

Heating capacity range [kW] **

Maximum airflow [m³/h]

Maximum horizontal range [m]

Number of rows [pcs.]

Capacity of water [dm³]

Maximum temperature of working fluid

 [°C]

120

Maximum working pressure [MPa]

1,6

Connection diameter [``]

3/4

Power supply [V] / Frequency [Hz]

230/50

Rated motor current [A]

Motor speed [rpm]

Motor power [W]

Protection degree IP [-]

54

Net weight [kg]

Noise [dB]

***

FARMER MC-3S- 3 stage 3450 m³/h

0

5

10

15

20

53,6

50,3

47,1

44,1

41,0

43,2

46,3

49,4

52,5

55,5

1,58

1,49

1,39

1,3

1,21

11

10

9

8

7

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

120/90

      

0

5

10

15

20

40,6

37,5

34,5

31,5

28,6

32,7

35,8

38,8

41,8

44,8

1,79

1,65

1,52

1,39

1,26

15

13

11

9

8

90/70

       

0

5

10

15

20

35,0

31,9

29,0

26,0

23,2

28,2

31,2

34,2

37,1

40,1

1,54

1,4

1,27

1,14

1,02

11

10

8

6

5

80/60

    

0

5

10

15

20

29,3

26,3

23,4

20,6

17,8

23,6

26,6

29,6

32,5

35,4

1,28

1,15

1,02

0,9

0,78

8

7

5

4

3

70/50

       

 

FARMER MC-3S- 3 stage 3450 m³/h

0

5

10

15

20

17,8

15,0

12,2

9,41

6,63

14,4

17,3

20,2

23,0

25,7

0,77

0,65

0,53

0,41

0,29

3

2

2

1

1

50/30

       

0

5

10

15

20

16,8

14,0

11,2

8,53

5,87

13,6

16,5

19,4

22,3

25,1

1,46

1,21

0,97

0,74

0,51

11

8

5

3

2

40/30

       

FARMER MC-3S- 3 stage 3450 m³/h

FARMER MC-3S- 3 stage 3450 m³/h

FARMER MC-3S- 3 stage 3450 m³/h

FARMER MC-3S- 3 stage 3450 m³/h

III STAGE

II STAGE

I STAGE

III STAGE

II STAGE

I STAGE

III STAGE

II STAGE

I STAGE

III 

STAGE

II 

STAGE

STAGE

III 

STAGE

II 

STAGE

STAGE

40,6
32,5
23,8

3,57 – 53,6

3450
2400
1500

19

2

2

0,84
0,65
0,54

1400
1050

750
190
150
120

27
56
50
48

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

Parameters

Supply/return water

 temperature [°C]

Dry bulb air inlet

temperature

 [°C]

Heating capacity [kW]

Dry bulb air outlet 

temperature

 [°C]

Water flow [m³/h]

Pressure drop in the heat 

exchanger

 [kPa]

2.4 

DEVICE DIMENSIONS

 MC-3S

 

 

6

60

 mm

 

: 696

 mm

 

3

84

 mm

height (A):
width (B)
depth (C)

Содержание FARMER MC-35

Страница 1: ...Technical documentation AIR WATER HEATERS IN STEEL CASING FARMER MC 3S REVENTON GROUP FARMER MC 3S...

Страница 2: ...ines the resistance of the engine tothewateringress itswaterproofness FanmotoroftheFarmerMChasIP54 5 protectionagainstaccesstohazardouspartsbywirewithadiameterof1mm ormoreandagainstdustinquantitieswhi...

Страница 3: ...17 3 20 2 23 0 25 7 0 77 0 65 0 53 0 41 0 29 3 2 2 1 1 50 30 0 5 10 15 20 16 8 14 0 11 2 8 53 5 87 13 6 16 5 19 4 22 3 25 1 1 46 1 21 0 97 0 74 0 51 11 8 5 3 2 40 30 FARMER MC 3S 3 stage 3450 m h FAR...

Страница 4: ...fvalveonthesupplyandreturnofthedevice installationhastobesecuredagainstexcessiveincreaseofpressure it is recommended to check the leak tightness of the hydraulic system before plugging theelectricsupp...

Страница 5: ...C Operating mode continious or thermostatic Regulation accuracy 1 C Dimensions 130 x 85 x 40 mm Weight 210 g Degree of casing s protection IP 30 ProgrammablecontrollerHMI 3 stagespeedcontrollerwiththe...

Страница 6: ...ge speed controllers with thermostat A work in continuous mode B operation in thermostatic mode 5 Two way valve with actuator HC 6 Fan speed controller HC 7 Manual thermostat HC 8 Programmable control...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...ancewiththeinstructions using the device in the improper conditions too high humidity too high ortoo lowtemperature impactofthesurrounding sunetc modified equipment that has been modified or repaired...

Страница 14: ...Warranty card Reventon Group Ltd 3B Montazowa Street 43 300 Bielsko Bia a Poland...

Страница 15: ...Reventon Group Ltd 3B Montazowa Street 43 300 Bielsko Bia a Poland www reventongroup eu...

Отзывы: